FindTestingLabs
Registers collected 2026-08-22.See collection dates

IEC 61010-1 Accredited Testing Labs Worldwide

117 accredited laboratories in 17 countries hold IEC 61010-1 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, United Kingdom Accreditation Service. In the register, IEC 61010-1 scope entries most often cover Blood-Glucose, Laser Radiation, Lithium in Medical equipment, electrical safety and EMC, Electrical equipment, Water.

Total labs
117
Countries
17
Top matrix
Medical equipment, electrical safety and EMC
4 labs

Available in 17 Countries

Germany
35 labs
China
25 labs
United States
19 labs
United Kingdom
9 labs
Italy
6 labs
Japan
6 labs
Canada
4 labs
Poland
3 labs
India
2 labs
Taiwan
2 labs
Finland
2 labs
Sweden
1 lab
France
1 lab
Cyprus
1 lab
South Korea
1 lab
Netherlands
1 lab
Saudi Arabia
1 lab

Top matrices for IEC 61010-1

Top analytes for IEC 61010-1

  • Blood-Glucose (1)
  • Laser Radiation (1)
  • Lithium (1)
  • Rf Exposure (1)

Sample labs

TUV Rheinland (India) Pvt.
Bengaluru, IN

Test: Test Method(s)1,2: Automatic and semi-automatic laboratory equipment for analysis and other purposes IEC 61010-2-081; EN IEC 61010-2-081 laboratory equipment for the heating of materials IEC 61010-2-010; EN IEC 61010-

TÜV SÜD Industrie Service GmbH Prüflabor Technische Ausrüstung der Abteilungen Kälte- und Klimatechnik sowie Feuerungs- und Wärmetechnik
München, DE

DIN EN 61010 -1 2020-03 Sicherheitsbestimmungen für elektrische Mess -, Steuer -, Regel- und Laborgeräte - Teil 1: Allgemeine Anforderungen DIN EN 61010 -2-201 2019-04 Sicherheitsbestimmungen für elektrische Mess -, Steuer -,

Bay Area Compliance
Sunnyvale, CA, US

IEC 61010-1:2010+AMD:2016; UL 61010-1; UL 61010-2-010 (2019); UL 61010-2-081 (2019); UL 61010-2-101 (2019); CAN/CSA C22.2 No. 61010-1-12; CAN/CSA C22.2 No. 61010-2-101:19; CAN/CSA C22.2 No. 61010-2-081:19; CAN/CSA C22.2 No. 61010-

SHENZHEN STS TEST SERVICES CO.,LTD.
Shenzhen, CN

Test Technology: Test Method(s): Product Safety (Cont’d) IEC/EN BS EN 60695-10-2; IEC/EN BS EN 60695-2-10; IEC/EN BS EN 60695-2-11; IEC/EN BS EN 60695-2-12; IEC/EN BS EN 60695-2-13; IEC/EN/BS EN 61010-2-101(excludin

Kiwa Primara
Kaufbeuren, DE

DIN EN 61010-2-101 : 2017-10 Sicherheitsbestimmunge n für elektrische Mess-, Steuer-, Regel- und Laborgeräte - Teil 2-101: Besondere Anforderungen an In- vitro-Diagnostik (IVD)-Medizingeräte (IEC 61010-2-101:2015); Deutsche Fassung EN 610

Intertek Testing & Certification
Essex, GB

IEC 61010-1:2010 Excluding: Clause 12.2.3, Implosion of cathode ray tubes Clause 12.3, UV radiation Clause 12.5, Ultrasonic test Clause 12.6, Lasers General requirements and equipment for which there is no Part 2 standard

TUV Rheinland (Shenzhen) Co.,
Shenzhen, CN

IEC 61010-1 Edition 3.1 2017-01 CONSOLIDATED VERSION; ANSI/UL 61010-1 3rd Ed, dated May 12, 2012 with revision through July 19, 2019 19-34 19-41 IEC 80601-2-30 Edition 2.0 2018-03; ANSI/AAMI IEC 80601-2-30:2018 3-123 IEC 60601-2-35

DEKRA Certification
Sterling, VA, US

IEC 61010-1; IEC 61010-1:2010 + Amd 1:2016 + COR 1:2019; EN 61010-1:2010 + A1:2019 + AC:2019-04; IEC 60335-1; IEC 60335-1:2020 + A1:2025; EN IEC 60335-1:2023 + A11:2023; IEC 60335-2-14; IEC 60335-2-14:2025 (Ed. 7.0); EN IEC 603

TUV SUD Japan
Tokyo, JP

IEC 61010-1:2010 (Only sections 4.4, 5.1.3, 5.3, 6.2, 6.3, 6.5.2, 6.7, 6.8, 8.2, 10, 12.5.1); EN 61010-1:2010 (Only sections 4.4, 5.1.3, 5.3, 6.2, 6.3, 6.5.2, 6.7, 6.8, 8.2, 10, 12.5.1); JIS C 1010-1:2014 (Only Sections 4.4, 5.3, 5.1.3,

Cosmos Corporation
Matsusaka-shi, Mie, JP

IEC 61010-1:2010 + A1:2016; EN 61010-1:2010 + A1:2019; UL 61010-1:2012; CAN/CSA-C22.2 No. 61010-1:2012; JIS C1010-1:2014; JIS C1010-1:2019 (Excluding cl.12.2.1) Household and Similar Electrical Appliances - Safety - Part 1: General

Kiwa Nederland
RIJSWIJK ZH, NL

IEC 61010-1 and part: 2-010, 2-030, 2-040, 2-081, 2-101 EN-IEC 61558-1 and part: 2-6, 2- 16 EN-IEC 62368-1, EN-IEC 62790 IEC 62990-1 EN 230 EN 298 EN 1643 EN 12067-2 EN 13611 EN 14459 EN 45544-1, -2 and -3 EN 50104 NEN-EN 5029

TÜV NORD CERT
Essen, DE

DIN EN 61558 -2-6 2010-04 Sicherheit von Transformatoren, Drosseln, Netzgeräten und dergleichen für Versorgungsspannungen bis 1100 V - Teil 2-6: Besondere Anforderungen und Prüfungen an Sicherheitstransformatoren und Netzgeräte, die

SALUS ENGINEERING INTERNATIONAL
SANTA CLARA, CA, US

IEC 61010-1, IEC 60204-1; EN 61010-1, EN 60204-1 Information technology equipment, including UPS systems and electronic control equipment NFPA 790, NFPA 791; UL 62368-1; IEC 62368-1; EN 62368-1 Hazardous location equipment tha

Testo Industrial Services
Kirchzarten, DE

Fachbereich Norm / Ausgabedatum Hausverfahren / Version Titel der Norm oder des Hausverfahrens Einschränkungen Elektrotechnik DIN EN IEC 61010 -031 : 2024-05 (VDE 0411-031): 2024-05 IEC 61010-031:2022 Sicherheitsbestimmungen für

TUV Rheinland Italia
Pogliano Milanese, IT

TUV Rheinland Italia S.r.l. Via Mattei 3 20005 Pogliano Milanese MI Allegato al certificato di accreditamento n. 00321 rev. 5 del 25/06/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 72 Sede A Data: 29/09/2025 pag. 8 di 64 Appar

TUV SUD America
San Diego, CA, US

IEC 61010-1 Edition 3.1 2017-01 19-34 ANSI UL 61010-1 3rd Ed, dated May 12, 2012 with revision through July 19, 2019 19-41 IEC 80601-2-30: Edition 2.0 2018-03 3-123 ANSI AAMI IEC 80601-2-30:2018 3-123 IEC 80601-2-60 Edition 2.0 2019-06

TUV SUD Certification and Testing (China) Co., Ltd. Shenzhen Branch
Shenzhen, CN

Test Technology: Test Method(s): IEC 61010-2-081; EN IEC 61010-2-081; BS EN IEC 61010-2-081; UL 61010-2-081; CSA C22.2 No. 61010-2-081 IEC 61010-2-201; EN IEC 61010-2-201; BS EN IEC 61010-2-201; UL 61010-2-201; CSA C22.2 No.

Showing labs 101117 of 117. Use pagination below to see more.