Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory

ISO 7637-2 Accredited Testing Labs in United States

56 laboratories in United States are accredited by A2LA to perform ISO 7637-2 testing. We don't know yet whether 29 of them take outside work. From the accredited scope text: “ISO 7637-2: 1990 Road vehicles - Electrical di sturbance by conduction and coupling - Part 2 Commercial vehicles with nominal 24 V supply voltage - Electrical transient conduction along supply lines o” “ISO 7637-2; ISO 7637-3 Radio Communications Intentional Radiators 47 CFR FCC Part 15 C, E, F (using ANSI C63.10:2020 and/or FCC KDB 905462 D02 (v02). April 08, 2016); 47 CFR FCC Part 15D (using ANSI C” “ISO 7637-2, 2004/104/EC; UN ECE R10.04; EN 60945; IEC 60945; EN 14982; ETSI EN 301 489-1 through ETSI EN 301 489-52; EN 301 908-1 through EN 301 908-22; 3GPP TS 38.114 On the following products or typ” “ISO 7637-2; ISO 7637-3; ISO 13766-1; ISO 13766-2 ISO 14982; ISO 16750-2; UNECE Regulation 10, Revision 6, Electronic Sub-assemblies (ESA), Sections 6.7, 6.9, 7.17, 7.19 Wireless (Excluding HAC & SAR)”

Labs
56
Primary AB
A2LA56 labs

Accredited Labs

CKC Laboratories, Inc.

Mariposa, CA, US

Scope

ISO 7637-2: 1990 Road vehicles - Electrical di sturbance by conduction and coupling - Part 2 Commercial vehicles with nominal 24 V supply voltage - Electrical transient conduction along supply lines only ISO 7637-2 ISO 7637-2: 2011 ISO

View lab

The EMC Shop

Rocklin , CA, US

Scope

ISO 7637-2 Oscilloscope, voltage probe, 50 Ω & 1000 Ω load terminations RF Test Generators – Power Level Output Power Level Input Amplifier Gain (10 kHz to 1 GHz) 250 kHz to 1.0 GHz 250 kHz to 1.0 GHz

View lab

NOVASTAR SOLUTIONS.COM LLC DBA NOVASTAR METROLOGY

Livonia, MI, US

Scope

Parameter/Range Frequency CMC2, 4, 11 (±) Comments Frequency Modulation – Generate 3 FM Flatness Carrier Frequency: (11 to 13.5) MHz (88 to 108) MHz (352 to 432) MHz Rate Frequency: DC to 1

View lab

Advanced Test Equipment

San Diego, CA, US

Scope

ISO 7637-2 ISO 16750-2, UL1449, GR1089 Tektronix TDS5104 w/high voltage deferential probe & current probe Flicker & Harmonics – Measure Voltage Fluctuations (Flicker) Mains Harmonic Emissions 230V,

View lab

Compliance Management Group (CMG)

Marlboro, MA, US

Scope

ISO 7637-2 Conducted Transient Disturbances, Other than Supply Lines ISO 7637-3 Electrical Loads ISO 16750-2 Emissions Harmonics and Flicker EN 61000-3-2; IEC 61000-3-2; AS/NZS 61000.3.2; SANS 61000-3-2; EN 61000-3-3; IEC

View lab

UL LLC

Novi, MI, US

Scope

ISO 7637-2; SAE J1113-11 Electrical Disturbance by Conduction and Coupling/Electrical Interference by Conduction and Coupling ISO 7637-3; SAE J1113-12 Immunity to Magnetic Fields ISO 11452-8 Conducted Transient Emissions IS

View lab

DEKRA Certification

Plymouth, MI, US

Scope

ISO 7637-2 (2004, 2011); ISO 7637-2; ECE Regulation 10.06, Annex 10 Immunity Bulk Current Injection (BCI) ISO 11452-4 (2005); ISO 11452-4 (2011, 2020) (excluding TWC Method); SAE J113-4; IEC 61000-4-6; EN 61000-4-6; ECE Regu

View lab

TUV SUD America - Plymouth

Plymouth, MI, US

Scope

ISO 7637-2 (2004, 2011) (Supply Lines only); ISO 7637-3 (2007, 2016) (Capacitive & Inductive Coupling via other than supply lines); ECE Regulation 10.05 Annex 10; ECE Regulation 10.06 Annex 10 Transient Emissions ISO 7637-2 (200

View lab

Element Materials Technology Fremont Newark

Fremont, CA, US

Scope

ISO 7637-2; ISO 7637-3; ISO 13766-1; ISO 13766-2 ISO 14982; ISO 16750-2; UNECE Regulation 10, Revision 6, Electronic Sub-assemblies (ESA), Sections 6.7, 6.9, 7.17, 7.19 Wireless (Excluding HAC & SAR)

View lab

Element Materials Technology - Melbourne

Melbourne, FL, US

Scope

ISO 7637-2:2011 Lightning RTCA/DO-160, Section 22 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a perio

View lab

Element Materials Technology Chicago - Mt. Prospect

Mount Prospect, IL, US

Scope

ISO 7637-2 Conducted Transient Immunity via lines other than supply lines ISO 7637-3 ESD ISO 10605; ISO 10605:2008 Immunity of vehicles to electromagnetic disturbances from Off-vehicle radiation sources (Absorber-Lined Shielded

View lab

Intertek Testing Services NA

Kentwood, MI, US

Scope

ISO 7637-2; SAE J113-11; SAE J1113-42; ISO 7637-2 Ed. 2; ISO 7637-3; SAE J1113-12; ISO 7637-3 Ed. 2; ISO 7637-4 Absorber-Lined Shielded Enclosure (ALSE) (200 V/m, 80 MHz – 18 GHz) ISO 11452-2; SAE J1113-21; ISO 11452-2 Ed.2; IS

View lab

Element Materials Technology Rockford

Rockford, IL, US

Scope

ISO 7637-2 Generic and Product Family Standards EN/IEC 61000-6-1; AS/NZS 61000.6.1; EN/IEC 61000-6-2; AS/NZS 61000.6.2; EN/IEC 61000-6-3; EN/IEC 61000-6-4; CISPR 14-2; EN 55014-2; AS/NZS CISPR 14-2; CISPR 24; EN 55024; AS/NZS CI

View lab

Elite Electronic Engineering

Downers Grove, IL, US

Scope

ISO 7637-2 (including emissions); ISO 7637-3; ISO 7637-4; ISO 16750-2, Sections 4.6.3 and 4.6.4; ISO 21498-1; ISO 21498-2; CS.00054, Section 5.9; CS.00244 Section 5.2.15 through 5.2.21; CS.00245; CS.00246 Section 5.2.4; EMC-CS-2009.1

View lab

HCT America

Milpitas, CA, US

Scope

ISO 7637-2; SAE J1113-11; UN ECE Regulation 10; ISO 14982; ISO 14982-1; ISO 13766-1; EN ISO 13766-1; BS EN ISO 13766-1; AS ISO 13766.1 Conducted Transient Immunity (Other than Supply Lines) ISO 7637-3; SAE J1113-12 Electrical L

View lab

UL Verification Services

Fremont, CA, US

Scope

ISO 7637-2; ISO 7637-2 (2004, 2011) (Supply Lines only) Electrical Transients other than Supply Lines ISO 7637-3; ISO 7637-3 (2007, 2016) (Capacitive & Inductive Coupling via other than supply lines) The United Nations Economic Com

View lab

Applus Reliable Analysis

Madison Heights, MI, US

Scope

ISO 7637-2 Conducted Immunity on Signal Lines ISO 11452-10 ISO 7637-3 (using CCC) Conducted Transient Emissions ISO 7637-2 Electrical loads ISO 16750-2 Electrostatic Discharge (ESD) ISO 10605 Portable Transmitter RF Immunity IS

View lab

Radiometrics Midwest Corporation

Romeoville, IL, US

Scope

ISO 7637-2:2011 (12V Systems only) Screening Attenuation Measurements by Reverberation Chamber Method IEC 61726:2015 Screening Attenuation IEEE Std 299:2006 Electricity Meters Code for Electricity Metering (Basic Radiation Sus

View lab

Bay Area Compliance

Sunnyvale, CA, US

Scope

ISO 7637-2 (2011); ISO 11452-1 (2025); ISO 11452-2:2019; ISO 11452-4 (2020); ISO 11452-7 (2003); ISO 11452-8 (2015); ISO 11452-10 (2009); Ford ES-XW7T-1A278-AC; FMC 1278 (2016); GMW 3097; DC-10614 Military / Avionic MIL-STD 461G RE

View lab

Apex Test

Auburn Hills, MI, US

Scope

ISO 7637-2 Portable Handheld Transmitter Immunity ISO-11452-9 Radiated Immunity Reverb ISO-11452-11; IEC 61000 4-21 Conducted Transient Emissions ISO-7637-2 Transient Immunity on Supply Lines ISO-7637-2; ISO-7637-4 SAE J1113-

View lab

DEKRA Certification

Sterling, VA, US

Scope

ISO 7637-2; ISO 7637-2 (2004, 2011); Conducted Transient Immunity Supply Lines only ISO 7637-2; ISO 7637-2 (2004, 2011); ISO 7637-2 SAE J1113-11 Transient Immunity Capacitive & Inductive Coupling via other than supply lines

View lab

APTIV WESTFIELD TEST

Westfield, IN, US

Scope

ISO 7637-2; ISO 7637-2 (2004, Amd1:2008, 2011); ISO 16750-2; ISO 16750-2 (2012, 2023); FMC1278 (Rev 1-5); CS.00054 (2015, 2018); CS.00244 (2023); GMW3097 (2015-2024); ES-96200-00 (Rev 16-23)

View lab

Trescal, Inc. - Detroit

Howell, MI, US

Scope

Parameter/Range Frequency CMC2, 4, 6, 7 (±) Comments Absolute Power3 – Measure (+10 to +20) dBm (-30 to +10) dBm (-70 to -20) dBm (-10 to 0) dBm (-60 to -10) dBm 100 kHz to 4.2 GHz (4.

View lab

International Compliance

Neenah, WI, US

Scope

ISO 7637-2; ISO 16750-2 (Sections 4.4, 4.6.3 & 4.6.4) Harley Davidson Component EMC Engineering Guideline EG-812-22614 United Nations UNECE Emissions E/ECE/324 Addendum 9: Regulation 10, Annexes 7 and 8 Immunity E/EC

View lab

Element Materials Technology Burton

Burton, MI, US

Scope

ISO 7637-2 Conducted Transient Emissions; ECE Regulation 10 Annex 10 Conducted Transient Immunity – Power/Supply Lines ISO 7637-2 Conducted Transient Immunity; ISO 16750-2 Conducted Immunity (Pulses 4, 5a, 5b) ECE Regulation 10 An

View lab

TUV SUD America

San Diego, CA, US

Scope

ISO 7637-2, 2004/104/EC; UN ECE R10.04; EN 60945; IEC 60945; EN 14982; ETSI EN 301 489-1 through ETSI EN 301 489-52; EN 301 908-1 through EN 301 908-22; 3GPP TS 38.114 On the following products or types of products: Industrial

View lab

CETECOM

Milpitas, CA, US

Scope

ISO 7637-2; ISO 7637-3 Radio Communications Intentional Radiators 47 CFR FCC Part 15 C, E, F (using ANSI C63.10:2020 and/or FCC KDB 905462 D02 (v02). April 08, 2016); 47 CFR FCC Part 15D (using ANSI C63.17:2015); 47 CFR FCC Parts

View lab

Ditch Witch Compliance Testing Service

Perry, OK, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2 Susceptibility (Radiated) ISO 13766‐1; ISO 13766‐2; ISO 14982; ISO 11451-2; ISO 11452-2 Susceptibility (Conducted)1 ISO 13766‐1; ISO 13766‐2; ISO 14982; ISO 11451-4; ISO 11452-4 Susceptibility (Conducted Transient) IS

View lab

Stellantis - EMC Engineering and

Auburn Hills, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 7637-3

View lab

HELLA

NorthvilleTownship, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2 (2011); ISO 7637-2; GMW3097 (2015, 2019, 2022, 2024), Sections 3.5.1 and 3.5.2; GMW3097 Sections 3.5.1 and 3.5.2 Conducted Transient Immunity (other than Supply Lines) ISO 7637-3 (2016); ISO 7637-3; GMW3097 (2012, 201

View lab

HL Mando America Corporation

Auburn, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 16750-2 Electrical Transient Transmission by Capacitive and Inductive Coupling Via Lines Other Than Supply Lines ISO 7637-3

View lab

Molex

Lisle, IL, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 7637-3 Electrostatic Discharge (ESD) ISO 10605; IEC 61000-4-2 Electrical Loads ISO 16750-2 Insulation Resistance ISO 16750-2 Withstand Voltage / Dielectric Withstanding Voltage (DWV) ISO 16750-2; UL197

View lab

North American Lighting

Farmington Hills, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 16750-2:2012, Sections 4.6.3 and 4.6.4; FMC1278 (CI220, CI221, CI222); GMW 3097, Section 3.5

View lab

AUMOVIO

Auburn Hills, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 16750-2 (excluding Sections 4.10, 4.11, and 4.12) Electrical Transient Conduction on Lines other than Supply Lines ISO 7637-3 Electrostatic Discharge (ESD) ISO 10605 (2001); ISO 10605 (2008); ISO 10605 (202

View lab

ZF Global Electronics - Validation

Farmington Hills, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 16750-2 (Load Dump); CS-11979; CS00054; CS00244; FMC1278; MES_PW67602C; MES_PW67602D;

View lab

Valeo EMC Laboratory

Troy, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 7637-3; ISO 16750-2, Section 4.6.4 Radiated Immunity (Up to 6 GHz) ISO 11452-2 Electrostatic Discharge ISO 10605 Conducted Emissions IEC CISPR 25, Section 6.3 and 6.4 Conducted Transient Emissions

View lab

Vitesco Technologies

Auburn Hills, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2 Conducted and Transient Immunity ISO 7637-2; ISO 7637-3; ISO 16750-2 (excluding sections 4.10, 4.11, and 4.12)

View lab

leggett & platt

Detroit, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 7637-2 (2004, 2011) Electrical Transient Conduction Via Lines Other Than Supply Lines ISO 7637-3; ISO 7637-3 (2016) Electrical Loads ISO 16750-2, Sections 4.2, 4.3.1.2, 4.5, 4.6, 4.7, 4.8, 4.9 and 4.10.2; ISO 16750

View lab

John Deere Intelligent Solutions Group

Fargo, ND, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 7637-3 Section 4.5(CCC method); ISO 16750-2 Sections 4.4, 4.6.1, 4.6.2, 4.6.3, and 4.6.4; SAE J1455 Section 4.13.2; IACS-UR-E10 Rev 10 Sections 3, 4, 9 and 10; DNV-CG-0339 Sections 4, 5, 12 and 13; JDQ 202; U

View lab

N.S. International,

Auburn Hills, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 7637-3; ISO 16750-2 Radiated ISO 11452-2 Portable Transmitters ISO 11452-9 On the following products or types of products: Automotive Instrument Clusters and Heads UP Displays Equipment 1When the date, edition,

View lab

A. T. PARKER INC. DBA Solar Electronics

North Hollywood, CA, US

We don't know yet whether this lab takes outside work.
Scope

Parameter/Equipment Range CMC2, 3 (±) Comments LISNs Impedance Magnitude: 1 kHz to 150 MHz (150 to 400) MHz 400 MHz to 1 GHz Impedance Phase: (100 kHz to 10 MHz) (10 to 100) MHz (100 MHz to 1 GHz) Insertion Loss: (1 kHz t

View lab

Harman International North America Validation

Novi, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 7637-3 (2016), Sections 4.5 and 4.6 On the following products or types of products: Automotive Electronic Devices. 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories

View lab

BorgWarner

Kokomo, IN, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2 (2004, 2011); ISO 16750-2 (2012) Conducted Transient Immunity by Capacitive and Inductive Coupling (Other than Supply Lines) ISO 7637-3 (2007, 2016); ISO 7637-3 EFT/Burst Transient Immunity IEC 61000-4-4 (2004, 2012)

View lab

Ford Motor Company

Sunrise, FL, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2 (Annex F) Environmental Conditions and Testing for Electrical and Electronic Equipment Part 2: Electrical Loads ISO 16750-2 Radiated Immunity - Reverberation ISO 11452-11 On the following products: Automotive Electronic Equi

View lab

DENSO International America (DIAM)

Southfield, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2 (2004); ISO 7637-2; ISO 7637-3; ISO 16750-2, Section 4.6.4 ISO 10605; ISO 10605 (2008)

View lab

MAGNA INTERNATIONAL - MAGNA ELECTRONICS

Auburn Hills, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 7637-2 (2011); SAE J1113-11 Electrical Transients other than Supply Lines ISO 7637-3; ISO 7637-3 (2016, 2007); SAE J1113-12 Electrostatic Discharge (ESD) ISO 10605; ISO 10605 (2023, 2008); SAE J1113-13 Elec

View lab

NIDEC Mobility America Corporation EMC

Saint Charles,, IL, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2 (1990, 2004, 2011); ISO 7637-3 (1995, 2007, 2016) Conducted Emissions IEC CISPR 25 (2002, 2008, 2016, 2021), Voltage Method and Current Probe Method; BMW GS 95002-2 (2013,

View lab

AMETEK CTS US

Souderton, PA, US

We don't know yet whether this lab takes outside work.
Scope

Parameter/Equipment Range CMC2, 4, 7 (±) Comments ESD Simulators – Tip Voltage Rise Time Peak Current 30 ns Current 60 ns Current 65 ns Current 130 ns Current 180 ns Current 360 ns Current 400 ns Current 800

View lab

Joyson Safety Systems Acquisition

Pontiac, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2; ISO 16750-2 Electrical Transient on Lines other than Supply Lines ISO 7637-3 Immunity to Magnetic Fields (10 kHz to 150 kHz) ISO 11452-8 Portable Transmitters ISO 11452-9

View lab

Astemo Americas

Farmington Hills, MI, US

We don't know yet whether this lab takes outside work.
Scope

ISO 7637-2 (2004, 2011) On the following products and materials: Automotive components and subsystem level electronic and electromechanical devices. 1 When the date, edition, version, etc. is not identified in the scope of acc

View lab

Showing labs 1–50 of 56. Use pagination below to see more.

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.