IEC 61000-3-2 Accredited Testing Labs Worldwide
294 accredited laboratories in 20 countries hold IEC 61000-3-2 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, United Kingdom Accreditation Service. In the register, IEC 61000-3-2 scope entries most often cover Harmonic Current Emissions, Voltage, Radiated Emissions in Air, Electronic, Medical equipment, electrical safety and EMC.
Available in 20 Countries
Top matrices for IEC 61000-3-2
Top analytes for IEC 61000-3-2
- Harmonic Current Emissions (11)
- Voltage (6)
- Radiated Emissions (5)
- Impedance (5)
- Harmonics (5)
- Current Harmonics (5)
- Emissions (4)
- Harmonic Current (3)
Sample labs
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK 3C Test Ltd Issue No: 068 Issue date: 22 Aug
IEC 61000-3-2; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; JIS C 61000-3-2; KS C 9610-3-2 Flicker BS EN IEC 61000-3-3; IEC 61000-3-3; EN 61000-3-3; KS C 9610-3-3 Immunity Electrostatic Discharge (ESD) BS EN 61000-4-2; IEC 610
Test Technology: Test Method(s)1: Ring Wave Immunity EN 61000-4-12 (2017); EN 61000-4-12; IEC 61000-4-12 (2017); IEC 61000-4-12 Harmonic and Inter-harmonic Immunity IEC 61000-4-13 (2002); IEC 61000-4-13; EN 61000.4.13 (2009); E
Fachbereich Norm / Prüfverfahren (Ausgabestand) Titel der Norm oder des Prüfverfahrens Einschränkung EMV IEC 61000 -6-4:2018 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards -Emission standard for industrial envi
Test Technology: Test Method(s)1: Conducted Immunity (AC ports only) IEC 61000-4-6; EN 61000-4-6 Power Frequency Magnetic Field IEC 61000-4-8; EN 61000-4-8 Voltage Dips, Short Interruptions IEC 61000-4-11; EN 61000-4-11 Produc
Room 108, Building A, Lenovo Technology Port, No. 5899 Xiyou Road Economic and Technological Development Zone Hefei, Anhui Province, 230091, People’s Republic of China Test Technology: Test Method(s): Radiated and Conducted Emissi
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SHENZHEN DL TESTING TECHNOLOGY CO., LTD. 101-201, Comprehensive Building, Tongzhou Electronics Longgang Factory Area, No.1 Baolong Fifth Road, Baolong Community, Baolong Street, Longgang D
Bereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Normverfahren angeben) Prüfbereich / Einschränkung EMV IEC 61000-3-12:2011 Electromagnetic compatibility (EMC) -
UL International Italia Srl Via delle Industrie, 6 20061 Carugate MI Allegato al certificato di accreditamento n. 00999 rev. 6 del 16/07/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 27 Sede A Data: 16/07/2025 pag. 2 di 25 Appa
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 INTERTEK TESTING SERVICES LTD., SHANGHAI Building T52-8, No. 1201 Gui Qiao Road Pudong District, Shanghai, 201206, People’s Republic of China Emily Huang E-mail: Emily.J.Huang@interte
IEC 61000-3-2; B21 7112-OR; BT-LAH-HV Modul-EMV-V4.6; GWT A D05-02; Q/JLY J7110922C; MES PW 67602E; ECE R10 Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >
Bereich Norm oder Hausverfahren / Ausgabestand Titel der Norm oder des Hausverfahrens Einschränkungen zum Prüfverfahren EMV ÖVE/ÖNORM EN 61000-6-3:2011 Elektromagnetische Verträglichkeit (EMV) – Teil 6-3: Fachgrundnormen – Störau
IEC 61000-3-2:2019 + A1:2021 Nur 1-phasige Prüflinge EMV DIN EN 61000 -3-3 2023-02 Elektromagnetische Verträglichkeit - Anforderungen an Haushaltgeräte, Elektrowerkzeuge und ähnliche Elektrogeräte - Teil 2: Störfestigkeit - Produ
IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; GB 17625.1; BS EN IEC 61000‑3‑2; IEC 61000-3-12; EN 61000-3-12; BS EN 61000-3-12 Voltage Changes, Fluctuations, and Flicker IEC 61000-3-3; EN 61000-3-3; GB/T 17625.2; BS EN 61000-3-3;
IEC 61000-3-2 (2009, 2014, 2018 + A1:2021); AS/NZS 61000.3.2; KN 61000-3-2; KS C 9610-3-2 Voltage Fluctuations and Flicker EN 61000-3-3 (2008, 2013 + A1:2021); IEC 61000-3-3 (2008, 2013 + A1:2021); AS/NZS 61000.3.3; KN 61000-3-3
Test Technology: Test Method(s)1 : Medical electrical equipment - Part 2-75: Particular requirements for the basic safety and essential performance of photodynamic therapy and photodynamic diagnosis equipment IEC 60601-2-75; IEC 6
Test Technology: Test Method(s):1,2,3 Generic Product and Industry Specific Standards (EMC) (Cont.) TCN 68-210:2002 KN 24 (Annex 5) w/ RRA Announce 2014-92 (Dec. 29, 2014); KN 35:2013 (Annex 15); TCN 68-194:2000 Immunity Electro
Test Technology: Test Method(s): Flickers IEC 61000-3-3; EN 61000-3-3 Immunity Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2 Radiated Immunity IEC 61000-4-3; EN 61000-4-3 Electrical Fast Transient / Burst
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ELEMENT U.S. SPACE & DEFENSE 1536 East Valencia Drive Fullerton, California 92831 Vanessa Garcia Phone: (714) 879-6110 E-mail: vanessa.garcia@elementdefense.com Website: www.eleme
IEC 61000-3-2; EN 61000-3-2 Voltage Changes, Voltage Fluctuations and Flicker IEC 61000-3-3; EN 61000-3-3 Immunity Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2 Surge Immunity IEC 61000-4-5; EN 61000-4-5 Volta
Normative document: EN ISO/IEC 17025:2017 Registration number: L 022 of DEKRA Certification B.V. This annex is valid from: 18-06-2026 to 01-05-2030 Replaces annex dated: 08-01-2026 Dutch Accreditation Council RvA Page 36
IEC 61000-3-2; EN 61000-3-12; EN 61000-3-2; EN IEC 61000-3-2; GB 17625.1; IEC 61000-3-12; IEC 61000-3-2; KS C 9610-3-12; KS C 9610-3-2; SANS 61000-3-12; SANS 61000-3-2 Flicker and Fluctuations BS EN 61000-3-11; BS EN 61000-3-3;
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be
Certification Scheme Product Type / Category Standards / Requirements ITL Certification Scheme EMC Radio (cont’d) CISPR 32; EN 55032; KN 32; CNS 15936; CISPR 35; EN 55035; KN 35; IEC/EN 62233; IEC/EN 62311; IEC/EN 61000-6
Test: Test Method(s) 1,2 : Laboratory (cont.) IEC 61010-2-051; IEC 61010-2-061; IEC 61010-2-081; IEC 61010-2-101; IEC 61010-2-201; UL 61010-1; CAN/CSA C22.2 No. 1010.1; CAN/CSA C22.2 No. 61010-1; AS/NZS 61010; UL 61010-2-010; CS
18855 Adams Court Building AM1, AM2 Morgan Hill, CA 95037 Test Technology: Test Method(s): Emissions Radiated and Conducted (3m semi-anechoic chambers) CFR 47 FCC Part 15, Subpart B (using ANSI C63.4:2014); CFR 47 FCC Part 18 (
Test Technology: Test Method(s) 1: Immunity Electrostatic Discharge (ESD) AS/NZS IEC 61000.4.2; IEC/EN IEC/BS EN IEC 61000-4-2; GB 17626.2; GB/T 18287; GB/T24338.4; IEC/EN/BS EN 61960-3; EN/BS EN50155; EN/BS EN 50121-1; Ele
IEC 61000-3-2; BS EN 61000-3-3; EN IEC 61000-3-3 Immunity Generic or Product Specific IEC 60601-1-2 1; EN 60601-1-2:2015; BS 60601-1-2 2015; EN 60601-1-2:2007/AC:2010; BS 60601-1-2:2007/AC:2010; EN 14982; BS 14982; ISO 14982; IEC 6
Test Technology: Test Method(s)1: Voltage Dips and Short Interrupts (DC) AS/NZS 61000-4-29; BS EN 61000-4-29; IEC 61000-4-29 Product Family Standards CISPR 14-2; CISPR 35 Ring Wave Immunity Test BS EN 61000-4-12; IEC/EN 61000-4-
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540-3-2006 TRESCAL, INC 625 River Oaks Pkwy San Jose, CA 95134 Eddison Wong Phone: 408 444 9998 CALIBRATION Valid To: August 31
IEC 61000-3-2; BS EN 61000-3-2 EN 61000-3-3; IEC 61000-3-3; BS EN 61000-3-3 Immunity Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2 Electrical Fast Transient/Burst IEC 61000-4-4; EN 61000-4-4 Surge (AC mains power port
Test(s): Test Method(s) 1: Electrical Fast Transient (EFT) IEC 61000-4-4; EN 61000-4-4 First-Level and Second-Level Lightning Surge (Surge) GR-1089-CORE (using IEC 61000-4-5, ITU-T K.20, and K.44); IEC 61000-4-5; E
This document is a translation. The definitive version is the original German annex to the accreditation certificate. Technical Field Standard / Version Title of standard or in house procedure Test Area / Restriction EMC DIN EN 610
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren 1 Elektromagnetische Verträglichkeit (EMV) 1.1 Grundnormen EMV DIN EN 61000 -4-2 VDE 0847-4-2:2009
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV DIN EN 61000 -6-4:2011 -09 Elektromagnetische Verträglichkeit (EMV) Teil 6-4: Fachgrundnormen – Störa
ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pin e Tre e s, Ch e rts ey La n e , Sta ine s -u po n-Tha me s , TW18 3 HR, UK Electromagnetic Testing Services Ltd Issue No: 017
IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3 Immunity Electrostatic Discharge (ESD) EN 61000-4-2; IEC 61000-4-2 Radiated Disturbances EN 61000-4-3; IEC 61000-4-3 Electrical Fast Transient/Burst EN 61000-4-4; IEC 61000-4-4 S
IEC 61000-3-2 Voltage Fluctuations and Flicker IEC/EN 61000-3-3; AS/NZS 61000.3.3; BS EN 61000-3-3 Immunity Electrostatic Discharge (ESD) IEC/EN 61000-4-2; BS EN 61000-4-2 Radiated Immunity IEC/EN 61000-4-3; BS EN 610
IEC 61000-3-2, 3-3, 3-11, 3-12)
Fach- bereich Norm oder Prüfverfahren (Ausgabestand) Titel der Norm oder des Prüfverfahrens Prüfbereich/ Einschränkung EMV IEC 61000-4-16:2015 Electromagnetic compatibility (EMC) - Part 4- 16: Testing and measurement techniques - Te
Test Technology: Test Method(s)2: Immunity Electrostatic Discharge (ESD) EN 61000-4-2; BS EN 61000-4-2; IEC 61000-4-2; GB/T 17626.2 Radiated Immunity EN 61000-4-3; BS EN 61000-4-3; IEC 61000-4-3; GB/T 17626.3 Electrical Fast
IEC 61000-3-2; EN 61000-3-2; EN 61000-3-2:2014; EN IEC 61000-3-2:2019+A1:2021; GB 17625.1; EN IEC 61000-3-2:2019+A2:2024; IEC 61000-3-3; EN 61000-3-3; EN 61000-3-3:2013; EN 61000-3-3:2013+A2:2021+AC:2022- 01; EN 61000-3-3:2013+A1:201
2.2 Sicherheit: Sicherheitsbestimmungen für elektri sche Mess-, Steuer-, Regel- und Laborgeräte /Safety requirements for electrical equipment for m easurement, control and laboratory use ..................................................
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfbereich / Einschränkungen EMV IEC 61000 -4-16:2015 Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques -
Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV IEC 61000 -4-3:2020 Edition 4.0 Electromagnetic compatibility (EMC) - Part 4-3: Testing and measu
WTLAB S.R.L. Via Andrea Mantegna 3-5 35020 Tribano PD Allegato al certificato di accreditamento n. 01077 rev. 4 del 23/01/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 26 Sede A Data: 22/12/2025 pag. 4 di 17 Variazioni di tensi
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Ein - schränkungen zum Prüfbereich EMV IEC TR 61000 -3-6:2008 Electromagnetic compatibility (EMC) – Part 3-6: Limits - Assessment of emission l
Kiwa CERMET Italia S.p.A. con socio unico UNI CEI EN ISO/IEC 17025:2018 Allegato al certificato di accreditamento n. 00233 rev. 9 del 01/11/2025 Corso Spagna 12 35127 Padova PD Revisione: 59 Sede A Data: 01/11/2025 pag. 1 di 2
IEC 61000-3-2; EN 61000-3-2; IEC 61000-3-12; EN 61000-3-12; SANS 61000-3-2; JIS C 61000-3-2
IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; SANS 61000-3-2 Flicker IEC 61000-3-3; EN 61000-3-3; SANS 61000-3-3 Immunity Electrostatic Discharge (ESD) IEC 61000-4-2; EN 61000-4-2; SANS 61000-4-2 Radiated Immunity IEC 61000-4-3
Showing labs 151–200 of 294. Use pagination below to see more.