FindTestingLabs
Registers collected 2026-08-22.See collection dates

IEC 61000-4-34 Accredited Testing Labs Worldwide

35 accredited laboratories in 9 countries hold IEC 61000-4-34 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle. In the register, IEC 61000-4-34 scope entries most often cover Current Harmonics, Output Voltage in Electrical equipment.

Total labs
35
Countries
9

Available in 9 Countries

Germany
14 labs
China
8 labs
United States
4 labs
Japan
3 labs
Taiwan
2 labs
Italy
1 lab
South Korea
1 lab
Sweden
1 lab
Finland
1 lab

Top matrices for IEC 61000-4-34

Top analytes for IEC 61000-4-34

  • Current Harmonics (1)
  • Output Voltage (1)

Sample labs

KSIGN Testing Co.,
Hangzhou, CN

IEC 61000-4-34; GB/T 17626.34; BS EN 61000-4-34 Generic and Product Specific Standards EN 61000-6-1; IEC 61000-6-1; GB/T 17799.1; BS EN IEC 61000-6-1; EN 61000-6-2; IEC 61000-6-2; GB/T 17799.2; BS EN IEC 61000-6

SGS Japan
Yokohama, JP

IEC 61000-4-34 1; IEC 61000-4-34 1; EN 61000-4-34 1 Specification for Semiconductor Processing Equipment Voltage Sag Immunity SEMI F471

UL Japan, Inc. - Kashima EMC
Chiba-ken, 289-0341, JP

IEC 61000-4-34, Standard equipment: oscilloscope, current transformer Parameter/Range Frequency CMC2, 5 (±) Comments4 Normalized Site Insertion Loss – Distance: (3 to 5) m Distance: 10 m 9 kHz to

Dectron 2.0
Färjestaden, SE

Ackrediteringens omfattning Provningslaboratorier enligt SS-EN ISO/IEC 17025:2018 Dectron 2.0 AB Färjestaden Ackrediteringsnummer 10496 A014959-001 Elektrisk provning EMC Metod Parameter Provtyp Fält EN 55011:2016+A1:2017 +A11:2020+A2:2021

JianYan Testing Group Shenzhen Co.,
Shenzhen, Guangdong, CN

IEC 61000-4-34

Siemens Aktiengesellschaft Type Test Laboratory Electronics Siemens Motion Control
Erlangen, DE

Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV IEC 61000 -4-29: 2000 Electromagnetic compatibility (EMC) – Part 4 - 29: Testing and measurement

CE-LAB GmbH. EMV-Prüfzentrum
Ilmenau, DE

Fach- bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfverfahren/ Einschränkungen EMV DIN EN IEC 61000-4-11:2021-10 VDE 0847-4-11:2021-10 Elektromagnetische Verträglichkeit (EMV) - Teil 4-11

VDE Prüf- und Zertifizierungsinstitut
Offenbach am Main, DE

Fach- bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen EMV DIN EN 61000‐4‐29 (VDE 0847-4-29) 2001-10 Elektromagnetische Verträglichkeit (EMV) - Teil 4-29: Prüf- und Messverfahren

CSA Group Bayern
Plattling, DE

IEC 61000-4-34: 2009 Electromagnetic compatibil ity (EMC) – Part 4-34: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per pha

Intertek Testing Services NA
Duluth, GA, US

IEC 61000-4-34; EN 61000-4-34 (16 to 37 A) Aerospace standards Radio Frequency Susceptibility (Conducted) RTCA/DO-160G (Section 20.4) Radio Frequency Susceptibility (Radiated Anechoic Chamber Method) RTCA/DO-160G (Section

Bureau Veritas Consumer Products Services Germany
Schwerin, DE

EMV DIN EN 61000 -4-29 :2001 -10 VDE 0847-4-29:2001-10 (EN 61000-4-29:2000) Elektromagnetische Verträglichkeit (EMV) - Teil 4-29: Prüf- und Messverfahren; Prüfungen der Störfestigkeit gegen Spannungseinbrüche, Kurzzeitunterbrechun

BTL Inc.
New Taipei City, TW

IEC 61000-4-34; EN 61000-4-34; BS EN 61000-4-34 Product Family / Generic EMC standard EN 55024; CISPR 24; BS EN 55024 EN 55035; IEC/CISPR 35; BS EN 55035; SANS 2335; IEC 61000-6-1; EN 61000-6-1; BS EN 61000-6-1; EN IEC 61000-6-1;

Etteplan Finland Oy, Test
Jyväskylä, FI

T298/M23/2025 Liite 1 / Appendix 1 Sivu / Page 3(23) Vaatimus/Requirement SFS-EN ISO/IEC 17025:2017 17.12.2025 Päätöksen päiväys / Date of decision 22.07.2028 Päätöksen viimeinen voimassaolopäivä / Date of expiry www.finas.fi Voimass

GRG Metrology & Test Group Co.,
Shenzhen, CN

IEC 61000-4-34; EN 61000-4-34; BS EN 61000-4-34 Generic and Product Specific Standards EN IEC 61000-6-1; IEC 61000-6-1; AS/NZS 61000-6-1; BS EN IEC 61000-6-1; EN IEC 61000-6-2; IEC 61000-6-2; AS/NZS 61000-6-2; BS E

UL LLC
Novi, MI, US

IEC 61000-4-34; EN 61000-4-34; KS C IEC 61000-4-11; KS C IEC 61000-4-34 IEC 61000-4-39; EN 61000-4-39; KS C IEC 61000-4-39

QSES Inc. Testing Laboratory
Abiko-Shi, Chiba, JP

IEC 61000-4-34 1; EN 61000-4-11 1; KS C 9610-4-11 1; SEMI F47 1 1 This laboratory performs field testing activities for these tests.

HCT CO.,
Icheon-si, Gyungki-do, KR

Parameter/Equipment Range CMC2, 4 (±) Comments Dip Simulators3 – Output Voltage DC (50 to 60) Hz Output Frequency Dip & Up Voltage DC (0 to 12) V 0 % (0 to 40) % (40 to 70) % (70 to

RS Schwarze Industrieelektronik GmbH EMV-Laboratorium
Schloss Holte-Stukenbrock, DE

IEC 61000-4-34 EMV DIN EN 61000-6-2:2006 Elektromagnetische Verträglichkeit (EMV) - Teil 6-2: Fachgrundnormen - Störfestigkeit für Industriebereiche (IEC 61000-6-2:2005); Deutsche Fassung EN 61000-6-2:2005 EMV DIN EN 61000-6-2 Beric

Eurofins Product Service
Reichenwalde, DE

Fachbereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens (ggf. Abweichungen / Modifizierungen von Normverfahren angeben) Prüfbereich / Einschränkung EMV / EMC DIN EN 61000-4- 29:2001 Elektromagnetisch

Intertek Testing Services (Shanghai FTZ) Co.,
Shanghai, CN

IEC 61000-4-34; EN 61000-4-34; BS EN 61000-4-34; SANS 61000-4-34 Harmonics and Interharmonics Immunity EN 61000-4-13; BS EN 61000-4-13; SANS 61000-4-13; IEC 61000-4-13 Voltage Fluctuation Immunity EN 61000-4-14; BS EN 61000-

Intertek Deutschland
Kaufbeuren, DE

IEC 61000-4-34 Without PLC requirements EMV IEC 61851-23 Electric vehicle conductive chargi ng system – Part 23: DC electric vehicle charging station 11.12 only (EMC tests) EMV IEC 62040-2:2005 Uninterruptible power systems (UPS) - P

UL International Italia
Carugate, IT

UL International Italia Srl Via delle Industrie, 6 20061 Carugate MI Allegato al certificato di accreditamento n. 00999 rev. 6 del 16/07/2025 UNI CEI EN ISO/IEC 17025:2018 Revisione: 27 Sede A Data: 16/07/2025 pag. 4 di 25 Prov

Reliable Analysis (Shanghai)
Shanghai, 201319, CN

IEC 61000-4-34 Testing and measurement techniques – Voltage fluctuation immunity test for equipment with input current not exceeding 16 A per phase IEC 61000-4-14

TUV Rheinland (Shanghai) Co.,
Shanghai, CN

IEC 61000-4-34 Ring Wave BS EN 61000-4-12; EN 61000-4-12; GB/T 17626.12; IEC 61000-4-12 Harmonics and Interharmonics BS EN 61000-4-13; EN 61000-4-13:2002; GB/T 17626.13; IEC 61000-4-13 Radiated Fields Immunity in Close Proximit

UL LLC/UNDERWRITERS LABORATORIES TAIWAN CO.,
Zhudong Township, Hsinchu County, TW

IEC 61000-4-34; EN 61000-4-34 Magnetic Fields IEC 61000-4-8; EN 61000-4-8 Second-Level Power Fault GR-1089-CORE Input DC Voltage GR-1089-CORE (using ATIS-0600315) Minimum O

SGS Germany
Puchheim, DE

IEC 61000-4-34:2005 +A1:2009 Electromagnetic compatibility (EMC) – Part 4-34: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16

TÜV SÜD Product Service GmbH PS-SL-EMC / PS-SL-ENV-STR
Straubing, DE

Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfbereich / Einschränkungen EMV DIN EN 61000 -4- 28:2009-12;VDE 0847-4-28:2009-12 Elektromagnetische Verträglichkeit (EMV) - Teil 4-28: Prü

TUV Rheinland of North America
Pleasanton, CA, US

IEC 61000-4-34; EN 61000-4-34 Ring Wave IEC 61000-4-12; EN 61000-4-12 Low Frequency Conducted Disturbance IEC 61000-4-16; EN 61000-4-16 Automotive (Generic) UNECE REG 10; EU 2015/208:2018 AUTOMOTIVE Electrostatic Discharge (ESD) I

cetecom advanced
Saarbrücken, DE

IEC 61000-4-34:2005 + A1:2009 + Cor. :2009); German version EN 61000-4-34:2007 + A1:2009 ☒ ESS Max. 3 x 480 V Max. 32 A per phase ☐ SB EMC DIN EN 61000 -4-39:2019 -04 Electromagnetic Compatibility (EMC) - Part 4-39: Testing

PHOENIX TESTLAB
Blomberg, DE

IEC 61000-4-34:2005 + A1:2009 + Cor. :2009); Deutsche Fassung EN 61000-4-34:2007 + A1:2009 ≤ 32 A / Phase EMV IEC 61000-4-34:2005 + A1:2009 + Cor.:2009 Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techni

Intertek Testing Services Zhejiang
Haining, Zhejiang, CN

IEC 61000-4-34; EN 61000-4-34; BS EN 61000-4-34; SANS 61000-4-34 Ring Wave Immunity IEC 61000-4-12; EN 61000-4-12; BS EN 61000-4-12; SANS 61000-4-12 Harmonics and Interharmonics Immunity IEC 61000-4-13; EN 61000-4-13; BS EN 610

DEKRA Testing and Certification (Suzhou) Co.,
Suzhou, Jiangsu Province, CN

IEC 61000-4-34; EN 61000-4-34; GB/T 17626.34 Ring Wave Immunity IEC 61000-4-12; EN 61000-4-12; GB/T 17626.12 Radiated Fields in Close Proximity Immunity IEC 61000-4-39; EN IEC 61000-4-39; GB/T 17626.39 Broadband Impulsive Condu

AKUVIB Engineering and Testing
Bochum, DE

Fachbereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens Prüfbereich / Einschränkung EMV DIN EN 61000-4- 17/A2:2009-11;VDE 0847-4-17/A2:2009- 11 Elektromagnetische Verträglichkeit (EMV) - Teil 4-17: Prüf-

TÜV NORD CERT
Essen, DE

Fach- bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren EMV DIN EN IEC 61326-2-5:2022- 11 VDE 0843-20-2-5:2022-11 Elektrische Mess-, Steuer-, Regel- und Labo

Element Materials Technology Boxborough
Boxborough, MA, US

IEC 61000-4-34:2005 + A1:2009 Power Quality RTCA/DO-1602 C, D, E, F, & G (Section 16); MIL-STD-1399-3002 A & B; MIL-STD-7042 A, B, C, D, E, & F; MIL-STD-1275 B, C, & D; ATIS 0600315; ETSI/EN 300-132-2; ETSI/EN 300-132-3 Generic/P