ISO 7637-2 Accredited Testing Labs Worldwide
134 accredited laboratories in 18 countries hold ISO 7637-2 in their ISO/IEC 17025 scope. Primary accreditors include American Association for Laboratory Accreditation, Deutsche Akkreditierungsstelle, United Kingdom Accreditation Service. In the register, ISO 7637-2 scope entries most often cover Impedance, Voltage, Dc Voltage in Vehicles, Oil.
Available in 18 Countries
Top matrices for ISO 7637-2
Top analytes for ISO 7637-2
- Impedance (3)
- Voltage (2)
- Dc Voltage (1)
- Emf (1)
- Low Frequency Magnetic Field (1)
- Output Voltage (1)
- Rf Insertion Loss (1)
- Speed (1)
Sample labs
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfbereich / Einschränkungen 1.6 Military EM V MIL -STD -461G 2015 -12 - 11 DEPARTMENT OF DEFENSE INTERFACE STANDARD REQUIREMENTS FOR THE
Parameter/Equipment Range CMC2 (±) Comments RF Speed Guns – Speed (5 to 1000) m/s 0.09 m/s Agilent 33210A, HP 53152A, NSI-MI Technologies MI-210-26A Surge Generators3 – Voltage
ISO 7637-2:2011-03 Edition 3 Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only EMV ISO 7637-3:2016-07 Edition 3 Road vehicles - Electrical distu
ISO 7637-2: 2011 Range 12VDC - 24VDC, Level I - IV Fordonskomponenter Nej Only transient immunity, test pulse 1, 2a, 2b , 3a and 3b Transient tålighet ISO 16750-2: 2012 Range 12VDC - 24VDC, Level I - IV Fordonskomponenter Nej Only testi
ISO 7637-2:2011 Road vehicles − Electrical disturbances from conduction and coupling − Part 2: Electrical transient conduction along supply lines only EMV / EMC ISO 7637-3:2016 Road vehicles - Electrical disturbances from conduct
ISO 7637-2:2011 Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only 1.7 Verfahren von ausländischen Normungsorganisationen EMC ANSI C63.4:2014 Ame
Fachbereich Norm / Hausverfahren / Version Titel der Norm oder des Hausverfahrens 1 (ggf. Abweichungen / Modifizierungen von Normverfahren angeben) Prüfbereich / Einschränkung EMV DIN EN 61000 -3-3: 2014 VDE 0838-3: 2014 Elekt
ISO 7637-2:2011 RTCA/DO-160, Section 22 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a period of one ye
ISO 7637-2, ISO 7637-3) Vedere elenco dei dettagli delle prove flessibili/See list of flexible scope details Misure di emissione/Measurements of emission (CISPR 25) Prove di immunità a radio frequenza/Radio frequency immunity tests (IS
ISO 7637-2:1990, except Pulses 1, 12 and 24 v 2, 5 Emissions and Immunity ISO 7637-2:2004 ISO 7637-2: 2011 ISO 7637-3:1995 Harmonics & Flicker ISO 7637-3: 2007 Burst & Surge ISO 7637-3:2016 ISO 16
ISO 7637-2 - transients from DC motors acting as generators after the ignition is switched off Test pulse 2b, severity level IV according to ISO 7637-2 - electrical transient conduction via lines other than supply lines for
ISO 7637-2 (2011); GMW 3097 (2022), Section 3.5.1; CS.00244 (2023), Section 5.2.14; TL81000 (2021), Section 5.4.3.2; ECE R10.06 Conducted Immunity (CI): CI, Transients on Power Lines ISO 7637-2 (2011); GMW 3097 (2022), Section
ISO 7637-2:2011 Straßenfahrzeuge – Elektrische, leitungsgeführte und gekoppelte Störungen – Teil 2: Elektrische, leitungsgeführte Störungen auf Versorgungsleitungen. EMV ISO 7637-3:2007 Straßenfahrzeuge – Elektrische Störungen durch
ISO 7637-2; ISO 7637-3; ES-XW7T-1A278-AC (CI 210, CI 220, CI 230, CI 250, CI 260, CI 270, RI 130, RI 150); EMC-CS-2009.1 (CI 210, CI 220, CI 230, CI 250, CI 260, CI 270, RI 130, RI 150); FMC 1278 (CI 210, CI 220, CI 221, CI 222
ISO 7637-2:2004; ISO 7637-2:2011; GMW 3097:2019; GMW 3097:2022; GMW 3097:2024; TL 81000:2018; TL 81000:2021; TL 81000:2024 CS 00054; B21 7110-F; REQ-043878; FMC 1278; Ford EMC-CS-2009.1; JLR-EMC-CS-v1.0; Fiat 990110 01; Fiat 99011
ISO 7637-2:2011 Road vehicles -- Electrical disturbances from conduction and coupling -- Part 2: Electrical transient conduction along supply lines only EMV ISO 7637-3:2016 Road vehicles - Electrical disturbances from conduction and
ISO 7637-2; ISO 7637-3; Conducted and Transient Immunity ISO 13766-1; EN ISO 13766-1; ISO 13766-2; EN ISO 13766-2; ISO 14982; ECE Regulation 10 Annex 10; EN 50498; GB/T 21437.2; GB/T 21437.3 RF Immunity to Hand Portable
ISO 7637-2 A. EMC. E.33 Electric and electronic equipment Radio disturbances (ALSE method) 150 kHz – 2500 MHz EN 55025 (CISPR 25) A. EMC. E.34 Electric and electronic equipment Conducted Emissions, Voltage method (AAN me
Parameter/Equipment Range CMC2, 4, 8 (±) Comments 7637 Pulse Generator3 – Pulse 1, Pulse 2a, 2b, Pulse 3a, 3b, Pulse 5a, 5b: Vo lt a ge Rise Time Duration (0.1 to 660) V 1 ns to 5 µs 100 ns
ISO 7637-2 ; E/ECE/324;, ECE R 10, Regulation No. 10; IEC/SI 61851-1; MIL-STD-461C/D/E/F/G, RTCA/DO-160D/E/F/G
ISO 7637-2; ISO 7637-2 (2004, 2011); ISO 7637-3; ISO 7637-3 (2016); SAE J1113-11; SAE J1113-12 Conducted Transient Emissions ISO 7637-2; ISO 7637-2 (2004, 2011); SAE J1113-42 Electrical Transient ISO/TS 7637-4 R
ISO 7637-2; ISO 7637-2:2011 Conducted Transient Immunity Along Supply Lines ISO 7637-2; ISO 7637-2:2011 Conducted Transient Immunity Along Lines Other Than Supply Lines ISO 7637-3; ISO 7637-3:2016 Electrical Loads ISO 16
ISO 7637-2:2004 + A1:2008 2.4 Automotive Conducted Immunity - BCI 1 to 400 MHz Up to 100mA ISO 11452-4:2005 2.5 Transient Immunity UNECE Reg 10.5 Conducted immunity on supply l
ISO 7637-2:1990 and Voltage Tests ISO 7637-2:2011 ISO 7637-2:2004 ISO 7637-3:1995 ISO 7637-3:2007 ISO 7637-3:2016 Ford ES-XW7T-1A278-AB:1999 Section CI 210, CI 220, CI 230 CI 240, CI 250, CI 260 & CI 270 U
ISO 7637-2; ISO 7637-2 (2004); ISO 7637-4; SAE J1113-11 Conducted Immunity on Signal Lines ISO 11452-10; ISO 7637-3; ISO 7637-3 (2007); SAE J1113-12 Conducted Transient Emissions ISO 7637-1; ISO 7637-2; ISO 7637-2 (2004); ISO 763
ISO 7637-2:2011-03 Road vehicles – Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only EMV ISO 7637-3:2016-07 Road vehicles - Electrical disturbances from conduction
ISO 7637-2; GB/T 21437.2; ISO 7637-3; GB/T 21437.3; ISO 10605; GB/T 19951; UN ECE R10; SAE J1113-1; SAE J1113-4
ISO 7637-2; GB/T 33014.2 Immunity Electrostatic Discharge Testing ISO 10605; ISO 10605:2008+A1:2014; GB/T 19951 Radio Frequency Immunity Testing ISO 11452-2; GB/T 33014.2; ISO 11452-4; GB/T 33014.4; GB/T 33014.9; ISO 1145
ISO 7637-2:2004 Road vehicles - Electrical dist urbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only EMV ISO 7637-2:2011 Road vehicles - Electrical dist urbances from conduction and
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Prüfbereich / Einschränkungen EMV DIN EN 62841 - 1:2023-03; VDE 0740-1:2023-03 Elektrische motorbetriebene handgeführte Werkzeuge, transpor
Fachbereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Einschränkungen zum Prüfverfahren Mobilität - Automotive Equipment EMV DIN EN IEC 55025: 2023-11 Fahrzeuge, Boote und von Verbrennu
Bereich Norm oder Prüfverfahren / Ausgabestand Titel der Norm oder des Prüfverfahrens Ein - schränkungen zum Prüfbereich EMV EN 55025:2017 + AC:2017 Fahrzeuge, Boote und von Verbrennungsmotoren angetriebene Geräte - Funkstöreigen
ISO 7637-2 1These methods have been assessed by A2LA according to A2LA’s FDA ASCA Program requirements. Accreditation by A2LA does not imply FDA ASCA -Accreditation. All ASCA - accreditation decisions for testing laboratory application
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measur
This document is a translation. The definitive version is the original German annex to the accreditation certificate. Technical field Standard / In-house procedure / Version Title of standard or in house procedure (deviations / mod
ISO 7637-2:2011 Road Vehicles – Electrical disturbances from conduction and coupling – Part 2: Electrical transient conduction along supply lines only; 2011 EMV ISO 7637-3:2016 Road Vehicles – Electrical dist urbances from conduct
ISO 7637-2:2004/Amd1:2008, ISO 7637-2:2011 _ _ _ _ Prove di immunità ai campi elettromagnetici irradiati a banda stretta (BCI-Test)/Immunity to disturbances from narrowband radiated electromagnetic energy (BCI-test) (Fino a 100mA; Da
ISO 7637-2:2011 Straßenfahrzeuge - Elektrische, leitungsgeführte und gekoppelte Störungen - Teil 2: Elektrische, leitungsgeführte Störungen auf Versorgungsleitungen EMV ISO 7637-3:2016 Straßenfahrzeuge - Elektrische Störungen durc
ISO 7637-2 Radio Frequency Immunity Testing ISO 11452-2; ISO 11452-4; SAE J1113-21 Automotive Transients Immunity Testing ISO 7637-2; ISO 7637-3 (CCC only); ISO 16750-2 (Load Dump) Electrostatic Discharge Testing ISO 10605
ISO 7637-2 (including emissions); ISO 7637-3; ISO 7637-4; ISO 16750-2, Sections 4.6.3 and 4.6.4; ISO 21498-1; ISO 21498-2; CS.00054, Section 5.9; CS.00244 Section 5.2.15 through 5.2.21; CS.00245; CS.00246 Section 5.2.4; EMC-CS-2009.1
ISO 7637-2; SAE J1113-42; EN 50498 Conducted Transient Immunity GB/T 21437.2; ISO 7637-2; SAE J1113-11; EN 50498; ISO 7637-3; ISO 16750-2; GB/T 21437.3; GB/T 28046.2; SAE J1113-12 Harmonic Emissions IEC 61000-3-2;
ISO 7637-2; SAE J1113-11; UN ECE Regulation 10; ISO 14982; ISO 14982-1; ISO 13766-1; EN ISO 13766-1; BS EN ISO 13766-1; AS ISO 13766.1 Conducted Transient Immunity (Other than Supply Lines) ISO 7637-3; SAE J1113-12 Electrical L
ISO 7637-2; BS ISO 7367-2 Vehicles, Boats and Internal Combustion Engines CISPR 25; BS EN 55025; (Only ALSE method) Electrical/electronic Sub-assembly (ESA) Regulation No. 10 (Section 7, 8 and 10 only) Radio Wideband T
ISO 7637-2; SAE J1113-42; ES 96200-00; RNDS-C-00517 Conducted Transient Immunity ISO 7637-2; ISO 7637-3; ISO 16750-2; SAE J1113-11, 12; ES 96200-00; RNDS-C-00517; ETSI EN 301 489-1 (7637-2(2004) only) Magnetic Field Immunity
ISO 7637-2; ECE R10; GB/T 21437.2; VW TL81000; Jaguar JLR-EMC-CS-2010; Jaguar JLR-EMC-CS; GMW3097; Ford EMC-CS-2009.1; Ford FMC1278; BMW GS-95002-2; BMW GS-95002-5; Daimler MBN 10284-2; Daimler MBN 10284-4; Geely Q/JLY J711077
ISO 7637-2; ISO 7637-2 (2004, 2011) (Supply Lines only) Electrical Transients other than Supply Lines ISO 7637-3; ISO 7637-3 (2007, 2016) (Capacitive & Inductive Coupling via other than supply lines) The United Nations Economic Com
ISO 7637-2:1990 (pulses 1, 2, 3a, 3b and 5) ISO 7637-2:2011 ISO 7637-3: 2007 ISO 7637-3:2016 (excluding DCC method) ISO 11452-2:2012 (pulses 4, 5a, 5b load dump)
ISO 7637-2; SAE J1113-11 Coupled Transient Immunity along Lines Other Than Supply Lines ISO 7637-3; SAE J1113-12 Electrical Loads ISO 16750-2 Transient Conduction and Coupling Definitions and General Considerations ISO 76
ISO 7637-2 (section 4.4); SAE J1113-11; J1113-12 (excluding DCC method); EN 50498 (section 7.4); EN 13309 (section 4.9); ISO 13766 (section 5.10); E/ECE/324/Add. 9 R10 (section 6.9); ISO 7637-3; ISO 16750-2 (excluding section 4.10.3
ISO 7637-2:2004 + A1:2008 Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only EMC ISO 7637-3:1995 Road vehicles - Electrical disturbance by conductio
Showing labs 51–100 of 134. Use pagination below to see more.