Registers refreshed 2026-11-20.See refresh dates
Accredited lab directory

EN 55022 Accredited Testing Labs in United States

28 laboratories in United States are accredited by A2LA to perform EN 55022 testing. We don't know yet whether 5 of them take outside work. From the accredited scope text: “EN 55022: 2010 EN 55022: 2006+A1+A2 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement [table-top equipment only for testing above 1 GHz] EN 55024” “EN 55022; AS/NZS CISPR 22; SI 961 Part 24; CNS 13438 (up to 6 GHz); CNS 15936 (2016); CAN/CSA-CEI/IEC CISPR 22; KN 22; HKCA 1007; IEC/CISPR 32; EN 55032; KS C 9832; SANS 2332; CISPR 14-1; EN 55014-1;” “EN 55022; IEC/EN 55032; CISPR 32; EN 55103-1; KS C 9832; AS/NZS CISPR 11; AS/NZS CISPR 32; ICES-001; ICES-003; ICES-005; VCCI V-3; VCCI-CISPR 32 (up to 6 GHz); CNS 13803; CNS 13783-1; CNS 13438; CNS 1” “EN 55022; BS 55022; ICES-001; ICES-003, Issue 6; ICES-002; CISPR 11; CISPR 12; CISPR 22; CISPR 32; CAN/CSA CISPR 12; EN 14982; ISO 14982 Immunity Generic or Product Specific EN 60601-1-2:2015; BS 6060”

Labs
28
Primary AB
A2LA28 labs

Accredited Labs

CKC Laboratories, Inc.

Mariposa, CA, US

Scope

EN 55022: 2010 EN 55022: 2006+A1+A2 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement [table-top equipment only for testing above 1 GHz] EN 55024: 2010+A1 EN 55024: 2010 Informat

View lab

Eurofins Electrical and Electronic Testing NA

Littleton, MA, US

Scope

EN 55022; SANS 222; AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; VCCI-CISPR 32:2016; SANS 2332; IEC 62236-4 Harmonics IEC 61000-3-2; EN 61000-3-2; AS/NZS 61000.3.2; SANS 61000-3-2; IEC 61000-3-12; EN 61000-3-12; SANS 6100

View lab

Nebraska Center for Excellence in Electronics

Lincoln, NE, US

Scope

EN 55022; AS/NZS CISPR 22 (2002); SANS 222; CISPR 32; EN 55032; KS C 9832; AS/NZS 4771; AS/NZS 4268; AS/NZS CISPR 32; CNS 15936 (Up to 6 GHz); GB 9254 (1998); GB 17625.1 (2003); VCCI V-3-2011 (Up to 6 GHz); VCCI V-32; VCCI-CISPR 32

View lab

TUV SUD America

Alpharetta, GA, US

Scope

EN 55022; AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; EN 50121-4; EN 61000-6-3; EN 61000-6-4; EN 61326-1; EN 61326-2-6 Current Harmonics (single phase only) EN 61000-3-2; IEC 61000-3-2; JIS C 61000-3-2 Voltage Fluct

View lab

Intertek Testing Services NA

Skaneateles Falls, NY, US

Scope

EN 55022; AS/NZS CISPR 22; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; 47 CFR, FCC Part 15B (Using ANSI C63.4:2014); ICES-001; ICES-003 Medical Equipment IEC 60601-1-2 (Ed. 2, Ed. 3, Ed. 4, Ed 4+Am 1); ANSI AAMI IEC 60601-1-2:2014; I

View lab

Compliance Management Group (CMG)

Marlboro, MA, US

Scope

EN 55022; AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; SANS 2332 (all up to 6 GHz); CISPR 11; EN 55011; AS CISPR 11; KS C 9811; EN 55014-1 (excluding Measurements of Clicks); ICES-001; ICES-003; IEC 61800-3; KS C 9800-3;

View lab

UL LLC

Durham, NC, US

Scope

EN 55022; EN 55032; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; IEC 61800-3; EN 61800-3; CISPR 11; IEC/CISPR 11; IEC/CISPR 14-1; CISPR 14-1; CISPR 15; CISPR 32; CISPR 32: 2015 Edition 2.0;

View lab

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA

Austin, TX, US

Scope

EN 55022; CISPR 22; AS/NZS CISPR 22; KN 22; EN 55011; CISPR 11; AS CISPR 11; KS C 9811; EN 55014-1 (excluding measurements for clicks and disturbance power measurements (30 MHz to 300 MHz)); KS C 9814-1; VCCI V-3 (up to 6 GHz)

View lab

Element Materials Technology Chicago - Mt. Prospect

Mount Prospect, IL, US

Scope

EN 55022; CISPR 22; AS/NZS CISPR 22; EN 55032 (excluding Annex H); CISPR 32 (excluding Annex H); AS/NZS CISPR 32 (excluding Annex H); KS C 9832 (excluding Annex H) Current Harmonics EN/IEC 61000-3-2; AS/NZS 61000.3.2 Voltage F

View lab

Parker Hannifin Chomerics Test Services - Woburn, MA

Woburn, MA, US

Scope

EN 55022 (2006+A1:2007, 2010); EN 55032; KS C 9811; KS C 9814-1; KS C 9832 (341-2, excluding Broadcast Receivers); CNS 15936 (2016) (up to 6 GHz); CNS 13803; CNS 13783-1; AS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; CAN/CSA CISPR

View lab

Dayton T. Brown

Bohemia, NY, US

Scope

EN 55022 (Class B Devices only, up to 18 GHz); EN 55032; MIL-STD-461D/462D, Methods RE101, RE102; MIL-STD-461 (E, F, G), Methods RE101, RE102; RTCA/DO-160 (A, B, C, D, E, F, G), Section 21(Except Reverb); UK DEF STAN 59-41 (Part 3), S

View lab

Intertek Testing Services NA

Menlo Park, CA, US

Scope

EN 55022; AS/NZS CISPR 22; SI 961 Part 24; CNS 13438 (up to 6 GHz); CNS 15936 (2016); CAN/CSA-CEI/IEC CISPR 22; KN 22; HKCA 1007; IEC/CISPR 32; EN 55032; KS C 9832; SANS 2332; CISPR 14-1; EN 55014-1; KS C 9814-1; SANS 214-1; CISPR 1

View lab

Element Materials Technology San Jose, CA

San Jose, CA, US

Scope

EN 55022; IEC/EN 55032; CISPR 32; EN 55103-1; KS C 9832; AS/NZS CISPR 11; AS/NZS CISPR 32; ICES-001; ICES-003; ICES-005; VCCI V-3; VCCI-CISPR 32 (up to 6 GHz); CNS 13803; CNS 13783-1; CNS 13438; CNS 15936 (up to 6 GHz); TCVN 7189 (20

View lab

F2 Labs

Middlefield, OH, US

Scope

EN 55022; BS 55022; ICES-001; ICES-003, Issue 6; ICES-002; CISPR 11; CISPR 12; CISPR 22; CISPR 32; CAN/CSA CISPR 12; EN 14982; ISO 14982 Immunity Generic or Product Specific EN 60601-1-2:2015; BS 60601-1-2

View lab

Element Materials Technology Rockford

Rockford, IL, US

Scope

EN 55022; CISPR 22; AS/NZS CISPR 22; EN 55032; CISPR 32; AS/NZS CISPR 32; KS C 9832 Harmonics and Flickers IEC 61000-3-2:2018; IEC 61000-3-3:2013 +A1:2017 Immunity Electrostatic Discharge (ESD) 2 EN/IEC 61000-4-2; AS/NZS 610

View lab

TUV Rheinland of North America

Pleasanton, CA, US

Scope

EN 55022; CISPR 32; EN 55032; CNS 13803; CNS 13783-1; CNS 15936:2016; ICES-001; ICES-003, Issue 7; JIS C 1806-1; KS C 9811:2019; KS C 9814-1:2020; KS C 9815:2019; KS C 9832:2019; QCVN 118:2018/BTTTT; SANS 211; SANS 214-1; SANS 222;

View lab

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA

Santa Clara, CA, US

Scope

EN 55022; CISPR 22; AS/NZS/CISPR 11; AS/NZS/CISPR 22; AS/NZS/CISPR 32; RRL 2006-84; RRL 2005-128; RRL 2005-96; CISPR 11; EN 55011; KS C 9811; EN 55014-1 (excluding measurements of clicks); KS C 9814-1:2022; VCCI V-3 (up to 6 GHz);

View lab

Vista Laboratories, Inc.

San Clemente, CA, US

Scope

EN 55022; CISPR 32; EN 55032; AS/NZS CISPR 11; AS/NZS CISPR 14.1; AS/NZS CISPR 22; AS/NZS CISPR 32; 47 CFR FCC Part 18, (using MP-5:1986); 47 CFR FCC Part 15, Subpart B (using ANSI C63.4:2014); ICES-001; ICES-003; ICES-005; ICES-00

View lab

IIA LAB SERVICES

Alachua, FL, US

Scope

EN 55022 (2010); CISPR 22-2008 (Excluding Section 9.6); AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; EN 61000-6-3; IEC 61000-6-3; EN 61000-6-4; IEC 61000-6-4 Intentional Emissions Unlicensed Transmitters & Receivers U

View lab

International Compliance

Neenah, WI, US

Scope

EN 55022; EN 55032; ICES-001; ICES-003 Harmonic Current Emissions IEC 61000-3-2; EN 61000-3-2 Voltage Fluctuations and Flicker IEC 61000-3-3; EN 61000-3-3 Immunity Electrostatic Discharge (ESD) IEC 61000-4-2 Radiated Immu

View lab

TUV SUD America

New Brighton, MN, US

Scope

EN 55022; EN 55032; EN 61326-1; IEC 61326-1; EN 61326-2-6; IEC 61326-2-6; EN 61000-6-3; IEC 61000-6-3 (except IEC 61000-4-20); IEC/EN 61000-6-4; IEC/EN 61000-6-8 (except IEC 61000-4-20); EN 62233; IEC 62233; AS/NZS CISPR 14.1; AS

View lab

ElectroMagnetic Investigations

Hillsboro, OR, US

Scope

EN 55022; AS/NZS CISPR 22; CISPR 32; KS C 9832; AS/NZS CISPR 32; CNS 13438 (up to 6 GHz); IEC 61326-1; EN 61326-1; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; ICES-001; ICES-003; ICES-005;

View lab

CETECOM

Milpitas, CA, US

Scope

EN 55022; AS/NZS CISPR 22; CISPR 32 (excluding broadcast receivers); EN 55032; AS/NZS CISPR 32; VCCI-CISPR 32:2016; KS C 9832:2019; RRA Public Notification 2017-19, Dec 28, 2017; RRA Announce 2017-71, Dec 28, 2017; CNS 13438; IEC 6

View lab

Hewlett Packard Enterprise, Roseville Hardware Test & Compliance

Roseville, CA, US

We don't know yet whether this lab takes outside work.
Scope

EN 55022:2010; CISPR 32; EN 55032; CAN-CSA CISPR 32:2017; CISPR 32:2015+COR1:2016+A1:2019; EN 55032:2015+AC:2016+A1:2020+A11:2020; ICES-003 Issue 7; VCCI-CISPR 32; CNS 13438:2006 (up to 6 GHz); QCVN 118:2018/BTTTT; KS C 9832; CNS 15

View lab

EXTRON

Anaheim, CA, US

We don't know yet whether this lab takes outside work.
Scope

EN 55022 / CISPR 22 Ed. 6, 2008-09; CISPR 22; CISPR 32; EN 55032; EN / IEC 60601-1-2 Australia / New Zealand AS CISPR 11: 2017 + A1:2020; AS/NZS CISPR 22:2009 + A1:2010; AS/NZS CISPR 32:2015+A1:2020 South Africa SANS 211 / CISPR

View lab

Intel Corporation - Oregon CPRS

Hillsboro, OR, US

We don't know yet whether this lab takes outside work.
Scope

EN 55022:2010; EN 55022; EN 55032:2012/AC:2013; EN 55032:2015; EN 55032:2015/A11:2020; EN 55032; EN 61000-3-2:2014; EN 61000-3-2; EN 61000-3-3:2013; EN 61000-3-3; KS C 9811; KS C 9610-3-2; KS C 9610-3-3; KS C 9832 3m only; (exc

View lab

Schweitzer Engineering

Pullman, WA, US

We don't know yet whether this lab takes outside work.
Scope

EN 55022; EN 55022:2010 + AC:2011; CISPR 32:2015 + A1:2019; EN 55032; EN 55032:2012 (excluding Broadcast Receivers); ICES-001 Issue 5; ICES-003 Issue 7; CSA CISPR 11:19; CNS 13438:2006 (up to 6 GHz); AS/NZS CISPR 11; KS C 9811; K

View lab

Lexmark International

Lexington, KY, US

We don't know yet whether this lab takes outside work.
Scope

EN 55022:2010; EN 55022; CISPR 32:2012; CISPR 32:2015; CISPR 32; EN 55032:2012; EN 55032:2015; EN 55032; GB/T 9254:2008; GB/T 9254; GB/T 9254.1-2021; GB/T 9254.1; SANS 2332:2017; SANS 2332 Harmonics IEC 61000-3-2:2014; IEC 61000-3

View lab

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches