FindTestingLabs
Registers collected 2026-08-04 to 2026-08-05.See collection dates
ISO/IEC 17025 directory

FCC PART 15 Accredited Testing Labs in United States

37 laboratories in United States are accredited by A2LA under ISO/IEC 17025 to perform FCC PART 15 testing. From the accredited scope text: “FCC Part 15, Subpart C (using ANSI C63.10:2013); 47 CFR FCC Part 15, Subpart D (using ANSI C63.17:2013) 47 CFR FCC Part 15, Subpart E (using ANSI C63.10:2013 and FCC KDB Publication 905462 D02 (v02));” “FCC Part 15 G, Access Broadband Over Power Line (using ANSI C63.10-2013) White Space Device Intentional Radiators 47 CFR, FCC Part 15 H, White Space Device (using ANSI C63.10-2013) Canada (ISED) Inten” “FCC Part 15, Part B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using MP-5:1986); CFR 47, FCC Part 15, Part C (using ANSI C63.10:2013); ANSI C63.4:2009, 2014; ICES-001; ICES-003; ANSI C63.10:2013; V” “FCC Part 15, Subpart B (using ANSI C63.4:2014); CFR 47 FCC Part 18 (using MP-5:1986); IEC/CISPR 11; EN 55011; KS C 9811; CISPR 14-1 (excluding click and power disturbance); IEC/EN 55014-1; KS C 9814-1”

Labs
37
Primary AB
A2LA37 labs

Accredited Labs

Element Materials Technology Seattle - Bothell 120th

Bothell, WA, US

Scope

FCC Part 15, Subpart C (using ANSI C63.10:2013); 47 CFR FCC Part 15, Subpart D (using ANSI C63.17:2013) 47 CFR FCC Part 15, Subpart E (using ANSI C63.10:2013 and FCC KDB Publication 905462 D02 (v02)); 47 CFR FCC Part 15, Subpart F/G/H

View lab

Element Materials Technology Denver-Longmont

Longmont, CO, US

Scope

(A2LA Cert No. 214.43) Revised 2/16/2026 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ELEMENT MATERIALS TECHNOLOGY DENVER-LONGMONT 1736 Vista View Drive Longmont, CO 80504-5242 Mr. Thorsteinn Sigurdsson Phone: 425 2

View lab

Element Materials Technology Portland - Evergreen

Hillsboro, OR, US

Scope

FCC Part 15, Subpart B (using ANSI C63.4-2014; CFR 47, FCC Part 18 (using FCC MP-5:1986); ICES-GEN (Issue 2,February 2024); ICES-001 (Issue 5, July 2020); ICES-002 (Issue 7, September 2020); ICES-003 (Issue 7, October 2020); ICES-004

View lab

Core Compliance Testing Services

Hudson, NH, US

Scope

FCC Part 15, Subpart B (using ANSI C63.4:2014) Industrial, Scientific, and Medical (Consumer ISM) (up to 40 GHz) 47 CFR, FCC Part 18 (using MP-5:1986) Canada (ISED) ICES-001 Issue 5; ICES-003 Issue 7; ICES-005 Issue 5 EU

View lab

Nebraska Center for Excellence in Electronics

Lincoln, NE, US

Scope

FCC Part 15, Subpart B (using ANSI C63.4-2014); 47 CFR, FCC Part 18 (using MP-5:1986); CISPR 11; EN 55011; AS/NZS CISPR 11; KS C 9811; CISPR 12; EN 55012; CAN/CSA-CISPR 12-10; CISPR 14-1; EN 55014-1 (Excluding Clicks); CISPR 15; EN

View lab

Element Materials Technology Irvine

Irvine, CA, US

Scope

FCC Part 15, Subpart C (using ANSI C63.10;2013); 47 CFR FCC Part 15, Subpart D (using ANSI C63.17:2013); 47 CFR FCC Part 15, Subpart E (using ANSI C63.10:2013 and FCC KDB Publication 905462 D02 (v02)); KDB 291074 D02; 47 CFR FCC Part 1

View lab

TUV SUD America

Alpharetta, GA, US

Scope

FCC Part 15 C Unlicensed Transmitters (using ANSI C63.10-2013); ANSI C63.10-2013; ANSI C63.10-2020; ANSI C63.10-2020+Cor.1-2023; ANSI C63.10a-2024 UPCS 47 CFR, FCC Part 15 D Unlicensed Personal Communications Systems (using ANSI C6

View lab

EMTEK (Shenzhen) Co.,

Shenzhen, US

Scope

FCC Part 15 Subpart C (using ANSI C63.10:2013); CFR 47, FCC Part 15 Subpart D; CFR 47, FCC Part 15 Subpart E (using ANSI C63.10:2013 and FCC KDB 905462 D02 (v 02)); CFR 47, FCC Parts 22, 24, 25, 27, 30, 74, 90, 95, 9

View lab

Intertek Testing Services NA

Duluth, GA, US

Scope

Tests: Standard(s) 2: Industry Canada Radio Standards Specification (RSS in Category I Equipment Standards List) (excluding SAR) BETS-1; BETS-4; BETS-5; BETS-6; BETS-8; BETS-9; RSS-102 measurement (RF Exposure) (Issue 5); RSS-

View lab

Green Mountain Electromagnetics

Middlebury, VT, US

Scope

FCC Part 15 B (using ANSI C63.4:2014); CISPR 32; EN 55032; CISPR 11; EN 55011; VCCI-CISPR 32:2016; CNS 15936:2016; KS C 9832; IEC 60945, Sections 9.2 & 9.3 Harmonics/Flicker EN/IEC 61000-3-2; EN/IEC 61000-3-3 Immunity Elect

View lab

SGS North America

Sophia, WV, US

Scope

FCC Part 15 Subpart B (using ANSI C63.4-2014), Part 18 (using MP-5:1986); ICES-001; ICES-003; KS C 9811; VCCI V-3; CISPR 11; CISPR 32; EN 55011; EN 55032 Unintentional Radiators Radio Intentional Radiators (Unlicensed Transmitters)

View lab

UL LLC

Novi, MI, US

Scope

FCC Part 15, Subpart B (using ANSI C63.4-2014); ANSI C63.4-20142; 47 CFR, FCC Part 18 (using MP-5:1986); 47 CFR, FCC Part 18 (using ANSI C63.30-2021); MP-5:1986; ICES-GEN; ICES-001; ICES-003; ICES-005; EN 12895; EN ISO 14982 (1998)

View lab

Element Materials Technology Fremont Newark

Fremont, CA, US

Scope

Test: Test Method(s) 1: Wireless (Excluding HAC & SAR) (cont.) KS X 3123; KS X 3143; QCVN 18:2014/BTTTT; QCVN 47:2015/BTTTT; QCVN 55:2023/BTTTT; QCVN 73:2013/BTTTT; QCVN 74:2020/BTTTT; QCVN 88:2015/BTTTT; QCVN 94:2015/BTTTT

View lab

Element Materials Technology Washington DC

Columbia, MD, US

Scope

FCC Part 15B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using MP-5:1986); CFR 47, FCC Parts 15/C/E (without DFS)/F/G/H (using ANSI C63.10:2013) CFR 47, FCC Part 15E (with DFS) (using FCC KDB 905462 D02 (v02) - April 8, 2016);

View lab

EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA

Suite A Irvine, CA, US

Scope

FCC Part 15B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); ICES-001; ICES-003; EN 550323; CISPR 32; AS/NZS CISPR 32; KS C 9832; EN 55022; CISPR 22; AS/NZS CISPR 22; KN 22; EN 55011; CISPR 11; AS CISPR 11; KS C 981

View lab

TDK Test Services

Cedar Park, TX, US

Scope

FCC Part 15, Subpart B (using ANSI C63.4:2014) 1 When the date, edition, version, etc. is not identified in the scope of accreditation, laboratories may use the version that immediately precedes the current version for a period of one

View lab

Sporton International (USA)

Milpitas, CA, US

Scope

FCC Part 15 Subpart C, FCC Part 15 Subpart E, FCC Part 95 Subpart M, FCC Part 15 Subpart B; IEC CISPR 32, IEC CISPR 24 Hong Kong- Radio HKCA 1001; HKCA 1002; HKCA 1003; HKCA 1004; HKCA 1006; HKCA 1007; HKCA 1008; HKCA 1010; HKCA 1015

View lab

Element Materials Technology Minneapolis - Brooklyn Park

Brooklyn Park, MN, US

Scope

FCC Part 15, Subpart B (using ANSI C63.4-2014; 47 CFR, FCC Part 18, (using FCC MP-5:1986); ICES-GEN (Issue 2, February 2024); ICES-001 (Issue 5, July 2020); ICES-002 (Issue 7, September 2020); ICES-003 (Issue 7, October 2020); ICES-

View lab

International Certification Services

Glencoe, MN, US

Scope

FCC Part 15, Subpart B (using ANSI C63.4:2014); ANSI C63.4-2014 CFR 47, FCC Part 18 (using FCC MP-5:1986); CAN/CSA-CEI/IEC CISPR 11; CSA-CISPR 11; AS CISPR 11; ICES-001; ICES-003; ICES-005; CAN/CSA-CISPR 22; CISPR 13; BS EN 55011;

View lab

Motorola Solutions, Inc., Schaumburg

Schaumburg, IL, US

Scope

FCC Part 15, Subpart B ANSI C63.4:2014 Commercial Mobile Services (Conducted Testing Only) • FCC Part 22 (cellular) • FCC Part 24 • FCC Part 25 (below 3GHz) • FCC Part 27 TIA-603-E-2016; TIA-102.CAAA-F; ANSI C63.26:2015

View lab

Parker Hannifin Chomerics Test Services - Woburn, MA

Woburn, MA, US

Scope

FCC Part 15 Subpart B, (ITE devices) (using ANSI C63.4:2014); FCC Part 18 (using MP-5:1986); IEC/CISPR 11; IEC/CISPR 14-1; IEC/CISPR 22; IEC/CISPR 32; EN 55011; EN 55014-1; EN 55022 (2006+A1:2007, 2010); EN 55032; KS C 9811; KS C 981

View lab

Intertek Testing Services NA

Kentwood, MI, US

Scope

Test: Test Method(s) 1,2 : Laboratory (cont.) IEC 61010-2-051; IEC 61010-2-061; IEC 61010-2-081; IEC 61010-2-101; IEC 61010-2-201; UL 61010-1; CAN/CSA C22.2 No. 1010.1; CAN/CSA C22.2 No. 61010-1; AS/NZS 61010; UL 61010-2-010; CS

View lab

Element Materials Technology San Jose, CA

San Jose, CA, US

Scope

FCC Part 15, Subpart B (using ANSI C63.4:2014); CFR 47 FCC Part 18 (using MP-5:1986); IEC/CISPR 11; EN 55011; KS C 9811; CISPR 14-1 (excluding click and power disturbance); IEC/EN 55014-1; KS C 9814-1; CISPR 15; IEC/EN 55015; IEC/CI

View lab

F2 Labs

Middlefield, OH, US

Scope

FCC Part 15, Part B (using ANSI C63.4:2014); CFR 47, FCC Part 18 (using MP-5:1986); CFR 47, FCC Part 15, Part C (using ANSI C63.10:2013); ANSI C63.4:2009, 2014; ICES-001; ICES-003; ANSI C63.10:2013; VCCI-CISPR 32:2016 (up to 6 GHz);

View lab

TUV Rheinland of North America

Pleasanton, CA, US

Scope

FCC Part 15 B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using FCC MP-5:1986); CISPR 11; AS/NZS CISPR 11 (2004); EN 55011; CISPR 12; EN 55012; CISPR 14; EN 55014; KS C 9814-2; AS/NZS CISPR 14.1; CISPR 22; EN 55022; AS/NZS CISPR 2

View lab

Elite Electronic Engineering

Downers Grove, IL, US

Scope

FCC Part 15 B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using FCC MP-5:1986); ICES-001; ICES-003; ICES-005; IEC/CISPR 11, Ed. 4.1 (2004-06); AS/NZS CISPR 11 (2004); IEC/CISPR 11 Ed 5 (2009-05) + A1 (2010); KN 11 (2008-5) with RRL

View lab

HCT America

Milpitas, CA, US

Scope

FCC Part 15C/E/F/G/H (using ANSI C63.10:2020, FCC KDB 905462 D02, April 8, 2016 (v02)); 47 CFR, FCC Part 15D (using ANSI C63.17:2013); 47 CFR, FCC Part 20, 22, 24, 25, 27, 30, 73, 74, 80, 87, 90, 95, 96, 97, and 101 (using ANSI C63.26

View lab

UL Verification Services

Fremont, CA, US

Scope

FCC Part 15B (using C63.4:2014); ANSI C63.4; FCC OST/MP-5; ICES-Gen; ICES-001; ICES-003; ICES-005; ICES-006; CNS 13438; CNS 15936 (2016); SI 961 Part 32; EN 55103-1; IEC/CISPR 11; BS EN 55011; EN 55011; AS CISPR 11; IEC/CISPR 14-1;

View lab

Shenzhen UnionTrust Quality and Technology Co.,

Shenzhen,Guangdong, US

Scope

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SHENZHEN UNIONTRUST QUALITY AND TECHNOLOGY CO., LTD. 16/F, Block A, Building 6 Baoneng Science and Technology Park Longhua Street, Longhua District Shenzhen, Guangdong, People’s Republic of C

View lab

Vista Laboratories, Inc.

San Clemente, CA, US

Scope

FCC Part 15, Subpart B (using ANSI C63.4:2014); ICES-001; ICES-003; ICES-005; ICES-006; JEITA IT-3001; VCCI-CISPR 32:2016; CNS 13438 (up to 6 GHz); CNS 13783-1; CNS 13803; CNS 13439; CNS 15936:2016; CISPR 22; GB9254; KS C 9811:2019; KS

View lab

Radiometrics Midwest Corporation

Romeoville, IL, US

Scope

FCC Part 15B (using ANSI C63.4-2014); CFR 47, FCC Part 18 (FCC MP-5:1986); ICES-003, Issue 7; IEC CISPR 11:2015 (excluding DC-AN); IEC CISPR 22:2008; IEC CISPR 32:2015; EN 55011:2016 (excluding DC-AN); EN 55032:2015; MIL-STD 461E:199

View lab

DEKRA Certification

Sterling, VA, US

Scope

FCC Part 15 Subpart B (ANSI C63.4:2014) ; ANSI C63.4; CFR 47 FCC Part 18 (MP-5:1986) ICES-001; ICES-003 CISPR 32; CISPR 32:2015 + AMD1:2019 CSV (Ed. 2.1); EN 55032 ; EN 55032:2015 + A1:2020 (+A11) ; CISPR 11 2; EN 550112; EN IE

View lab

Element Materials Technology Boxborough

Boxborough, MA, US

Scope

FCC Part 15B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); ICES-003; CISPR 32 (excluding Annex H); EN 55032(excluding Annex H); KS C 9832 (excluding Annex H); CISPR 11; EN 55011; CISPR 14-1 (excluding disturbanc

View lab

International Compliance

Neenah, WI, US

Scope

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 INTERNATIONAL COMPLIANCE LABORATORIES, LLC 1057 Tullar Court Neenah, WI 54956 Ronald W. Zimmerman Phone: 920 720 5555 ELECTRICAL Valid to: April 30, 2026

View lab

TUV SUD America

San Diego, CA, US

Scope

FCC Part 15 G, Access Broadband Over Power Line (using ANSI C63.10-2013) White Space Device Intentional Radiators 47 CFR, FCC Part 15 H, White Space Device (using ANSI C63.10-2013) Canada (ISED) Intentional Radiators Licen

View lab

ElectroMagnetic Investigations

Hillsboro, OR, US

Scope

3650 NW McKibbin Road Forest Grove, OR 97116 Test Technology: Test Method(s) 1: Radiated Emissions (Open Area Test Site [OATS] – 3m and 10m) (up to 18 GHz) FCC CFR 47, Part 15, Subpart B (using ANSI C63.4); FCC CFR 47, Part

View lab

CETECOM

Milpitas, CA, US

Scope

Test: Test Methods: Immunity (cont’d) Surge EN 61000-4-5; IEC 61000-4-5; KS C 9610-4-5; CNS 14676-5 Conducted Immunity EN 61000-4-6; IEC 61000-4-6; KS C 9610-4-6; CNS 14676-6 Power Frequency Magnetic Immunity EN 61000-4-

View lab
Refine these results

This page is a fixed slice of the register: every FCC PART 15 scope we hold for United States. Search narrows it further by city, accreditation body, or a term from the scope text itself.

Search labs in United States

Top matrices for FCC PART 15 in United States

Top analytes for FCC PART 15 in United States

  • Emissions2
  • Ac Voltage1
  • Current Harmonics1
  • Emissions (Radiated And Conducted)1
  • Rf Exposure1

About ISO/IEC 17025 in United States

American Association for Laboratory Accreditation (A2LA) is the primary accreditation body issuing ISO/IEC 17025 accreditation for testing laboratories in United States.

ISO/IEC 17025 is the international standard for the competence of testing and calibration laboratories. Accreditation to this standard provides independent confirmation that a laboratory operates a quality management system and is technically competent to produce valid results within its declared scope.

Related searches