usCalibration
Irvine, CA, US
Parameter/Equipment Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (cont) (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50
Labs whose accredited scope includes electrical, mass, temperature or pressure calibration. Calibration compares a measuring instrument with a reference of known accuracy and states the difference and its uncertainty. 336 accredited labs in 27 countries have electrical, mass, temperature or pressure calibration in their scope. Most of them are in United States, Canada and Japan. The most common standards in these scopes are ANSI/NCSL Z540-1-1994, ASTM E18 and ASTM E4.
Instruments typically calibrated: multimeters, oscilloscopes, power supplies, electrical calibrators, balances, scales, weights, load cells, force machines, torque tools, thermometers, thermocouples, temperature baths, furnaces, climatic chambers, pressure gauges, pressure transducers, deadweight testers and vacuum gauges. Calibration of length and geometry instruments belongs to dimensional metrology.
Irvine, CA, US
Parameter/Equipment Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (cont) (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50
Lansdale, PA, US
Parameter/Equipment Range CMC2, 5 (±) Comments DC Current – Generate (0 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A 16 nA + 0.12 nA/µA
Albuquerque, NM, US
Parameter/Range Frequency CMC2, 6 (±) Comments Capacitance – Generate (220 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.999) nF (33 to 109.999) nF (110 to 329.999) nF (0.33 to 1.1)
Saginaw, MI, US
Parameter/Range Frequency CMC2, 5, 9 (±) Comments AC Current – Generate3 (cont) 330 µA to 3.3 mA (3.3 to 33) mA (33 to 330) mA 33 mA to 3 A (3 to 11) A (11 to 21) A (20
Shuaiba, KW
VI. Thermodynamics Parameter/Equipment Range CMC2, 3, 5 (±) Comments Temperature – Measuring Equipment (-40 to 150) °C (150 to 420) °C (420 to 660) °C 0.06 °C 0.07 °C 0.11 °C Temperature readout & RTD probe
Nuevo Leon, MX
Parameter/Equipment Range CMC2, 4, 6 (±) Comments Frequency – Measuring Equipment3 (0.01 to 11 999) Hz (12 to 2000) kHz (2 to 600) MHz 48 µHz/Hz + 6.3 mHz 0.042 % + 1.8 Hz 4.3 Hz/MHz + 5.9 kHz Fluke 552
New Berlin, WI, US
IX. Time & Frequency Parameter/Equipment Range CMC2, 9 (±) Comments Frequency – Fixed Point Measure 3 & Generate3 10 MHz 0.01 Hz to 1 kHz > 1 kHz to 1.3 GHz 1.0 × 10 -10 Hz/Hz 6.5 µHz + 0.12 µHz/H
Baton Rouge, LA, US
Parameter/Range Frequency CMC2, 4, 10 (±) Comments AC Voltage – Generate 3 (cont) 220 mV to 2.2 V (2.2 to 22) V (22 to 220) V (220 to 1100) V (220 to 750) V
Eden Prairie, MN, US
Parameter / Range Frequency CMC2, 6 (±) Comments Location8 AC Voltage – Generate (cont) (22 to 220) V (220 to 1100) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100
Santa Clara, CA, US
III. Electrical – DC/Low Frequency Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Current – Clamp-on Meter3 Toroidal (20 to 150) A (150 to 1000) A Non-Toroidal (20 to 150) A
Owatonna, MN, US
Parameter/Range Frequency CMC2, 6 (±) Comments AC Current – Measure3 (0 to 1) A (1 to 3) A (10 to 500) A (3 to 1000) A (3 to 5) Hz (5 to 10) Hz 10 Hz to 5 kHz (3 to 5) Hz (5 to 10) Hz 10 H
Madison, PA, US
Parameter/Equipment Range CMC2, 9 (±) Comments Infrared Temperature - Measuring Equipment 3 (-15 to 120) °C (120 to 200) °C (200 to 350) °C (350 to 500) °C 0.67 °C 1 °C 1.6 °C 2.2 °C Primary infra
Lenexa, KS, US
Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure3 (cont) (12 to 120) mV 120 mV to 1.2 V (1.2 to 12) V (12 to 120) V (120 to 700) V (0.70
New Taipei City, TW
III. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 6 (±) Comments DC Voltage – Generate3 (1 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 5) kV (5 to 10) kV 1
Alexandria, LA, US
Parameter/Range Frequency CMC 2, 4, 5, 6 (±) Comments AC Voltage – Measure3, 8 (cont) (1 to 10) V (10 to 100) V (100 to 750) V (0.75 to 10) kV (1 to 40) Hz 40 Hz to 1 kHz (1 to
Ottawa, CA
Parameter/Equipment Range CMC2, 7 (±) Comments Resistance – Generate 4 (0 to 10.9999) Ω (11 to 32.9999) Ω (33 to 109.9999) Ω (110 to 329.9999) Ω (0.33 to 1.099 999) kΩ (1.1 to 3.299 999)
Fairview, TN, US
Parameter/Range Frequency CMC2, 4 (±) Comments Capacitance3 – Generate (220.0 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1
Columbus, OH, US
IV. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measuring Equipment Digital Thermometers Liquid-in-glass Thermometers (-60 to 660) °C (-60 to 660) °C
Rixeyville, VA, US
Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate3 (cont) (33 to 329.99) mA (0.33 to 1.099 99) A (1.1 to 2.9999) A (3 to 10.999) A (11 to 20.5) A (10 to 45) H
Mentor, OH, US
AMS-2750 – temperature data logger & thermocouples VI. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Stopwatches & Timers3 Up to 24 hr 0.051 s/day Timometer ______________________
Draper, UT, US
Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage3 (cont) – Generate (2.2 to 22) V (22 to 220) V (220 to 1100) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz
Aliquippa, PA, US
(A2LA Cert No. 2332.01) Revised 2/16/2026 Page 14 of 20 Parameter/Range Frequency CMC2, 4 (±) Comments Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.999) nF (11 to 32.9999) nF (3
Bloomington, MN, US
1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope
Port Arthur, TX, US
Parameter/Range Frequency CMC2, 4 (±) Comments AC Current3– Generate (29 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1
Piedmont, SC, US
Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage3 – Generate (0.22 to 2.2) mV (2.2 to 22) mV (22 to 220) mV 220 mV to 2.2 V (2.2 to 22) V
Springboro, OH, US
VII. Time & Frequency Parameter/Equipment Range CMC2, 4, 8 (±) Comments Frequency – Measuring Equipment3 10 MHz DC to 10 MHz 10 MHz to 26.5 GHz 0.01 Hz to 2 MHz 1.5 nHz/Hz 1.5 µHz/Hz 1.5 nHz/Hz +
Mattoon, IL, US
Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Generate (0.029 to 330) µA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 3
Clayton, OH, US
Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (0.22 to 2.2) mV (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (
Webster, TX, US
Parameter/Equipment Range CMC2, 5 (±) Comments DC Voltage – Measure (0 to 200) mV (0.2 to 2) V (2 to 20) V (20 to 200) V (200 to 1000) V 0.26 µV 1.5 µV 14 µV 0.19 mV 1.3 mV Fluke 8508A DC Current – Genera
Huntsville, AL, US
Parameter/Range Frequency CMC2, 4, 5, 8, 13 (±) Comments AC Voltage – Generate3 (cont) (22 to 220) V (220 to 1100) V (220 to 1100) V (220 to 750) V (330 to 1020) V (10 to 20
Chattanooga, TN, US
Parameter/Range Frequency CMC2, 4, 5 (±) Comments AC Voltage – Generate3 (continued) (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50)
Caguas, US
VI. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Frequency – Generate 50 Hz to 20 MHz 50 Hz to 50 kHz 22 μHz/Hz 82 μHz/Hz Signal generator Multiproduct calibrator Freq
Lima, PE
DKD-R 5-7 calibration guideline of climatic chambers Thermo-hygrometer data loggers Storage & Transportation Unit Thermal Conditions – Spatial Survey/ Mapping Temperature Humidity (0 to 50) °C (30 to 82%) RH
Allentown, PA, US
Parameter/Range Frequency CMC2, 7 (±) Comments AC Voltage – Generate3 (1.0 to 12) mV (12 to 120) mV (0.12 to 1.2) V (1.2 to 12) V (12 to 120) V (120 to
Shelby Township, MI, US
VII. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment (Frequency Counters) 1 Hz to 10 kHz 0.58 Hz Signal generator _________________________ 1 This laborato
Evansville, IN, US
Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Generate3 Up to 329.9999 mV 330 mV to 3.299 999 V (3.3 to 32.999 99) V (33 to 329.9999) V (330 to 1020) V 0.007 % + 3.1 µV 0.006 % + 6.2 µ
Odessa, TX, US
Parameter/Range Frequency CMC2, 4, 5, 9 (±) Comments AC Voltage – Measure3 (1 to 10) mV (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V (100
San Diego, CA, US
Parameter/Range Frequency CMC2, 5, 7 (±) Comments AC Voltage – Generate3 (cont) (2.2 to 22) V (22 to 220) V (220 to 1100) V (250 to 750) V (300 to 500) kHz (0.5 to 1) MHz (10 to 20) H
Broussard, LA, US
Parameter/Equipment Range CMC2, 11 (±) Comments IR Temperature – Measure (100 to 400) °F 1.7 °F Precision IR thermometer Temperature – IR Systems – Measuring Equipment (100 to 400) °F 3.9 °F B
Olive Branch, MS, US
Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Measure3 Up to 750V (1 to 6) kV – Fixed Point 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz 60 Hz 0.12 % 0.21 % 0.82 % 1
Anaheim Hills, CA, US
CP-033, standard capacitor, decade capacitor Multifunction calibrator DC Current – Generate3 0 to 3.299 99) mA (3.3 to 32.9999) mA (33 to 329.999) mA 330 mA to 2.199 99 A (2.2 to 11) A (11 to 16.5) A (16.5 to 150) A (
Brampton, CA
Parameter/Range Frequency CMC 2, 5 (±) Comments Capacitance – Generate3 Measuring Instruments (0.19 to 0.4) nF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) µF (1
Columbia, MD, US
Parameter/Equipment Range CMC2 (±) Comments Load Cell Tension Compression (250 to 1500) lbf (>1500 to 5000) lbf (>5000 to 25 000) lbf (>25 000 to 50 000) lbf (>50 000 to 100 000) lbf (250 to 1500) lbf (>15
Boise, ID, US
Parameter/Range Frequency CMC2, 5 (±) Comments AC Voltage – Measure3 Up to 200 mV 200 mV to 2 V (2 to 20) V (20 to 200) V (200 to 1000) V (1
Yanbu, SA
Euramet cg-13 Indicator MilliK, SSPRT & S type TC, type (N) & type K TC sensor with thermometer indicator In-house method GMCL-TP05 GMCL-TP07 Yanbu, Tabuk Humidity – Measuring Equipment (10 to 95) % R
Greenville, SC, US
Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage3 – Measure (cont) 10 mV to 10 V (10 to 100) V (100 to 700) V Up to 10 kV (10 to 70) kV (1 to 40) Hz 40 Hz to
Harahan, LA, US
II. Electrical DC/Low Frequency Parameter/Equipment Range CMC2, 6 (±) Comments DC Voltage – Generate3 Fixed Point Up to 220 mV (0.22 to 2.2) V (2.2 to 11) V (11 to 22) V (22 to 220) V
Greensboro, NC, US
Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Voltage – Measure3 (10 to 100) mV, Locked on 100 mV Range 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 700) V (1 to 85) kV 40 Hz to
Thornton, CO, US
V. Time & Frequency _________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability (CMC) is th e smallest uncertainty of measurement that a laboratory can
Saco, ME, US
Parameter/Equipment Range CMC2, 4 (±) Comments DC Voltage – Generate (0.00 to 120) mV 120 mV to 1.2 V (1.2 to 12) V (12 to 120) V (120 to 1020) V 0.0009 % + 0.8 µV 0.0006 %
Showing labs 101–150 of 336.
Each lab page shows which of its certificates are active.